SDR Y2PA03025

Service difficulty report · Relay · Doug DC932F

Difficulty date
December 9, 2003
Submitted
August 26, 2004
Operation
Air carrier
Aircraft
N208US
Make and model
Doug DC932F
Aircraft serial
47220
Part
Relay
Part number
914F5674
Part serial
DM1452
Condition
Failed
Location
Apu
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW WORKING ELECTRICAL PROBLEM ON LT BUSS USING COM W/APU STARTED & RUNNING. APU LOW OIL PRESSURE LIGHT & OIL TEMP HIGH LIGHT ILLUM. APU SHUTDOWN. A/C OPS ON NR 2 GEN & BATTERIES. AN EMERGENCY DECLARED, A/C GIVEN DIRECT TO SDF & VECTORED FOR APPROACH. AIRCRAFT LANDED WITHOUT FURTHER INCIDENT AT SDF. NR 2 GENERATOR REMAINED OPERABLE DURING DESCENT AND LANDING. MANTENANCE DISPATCHED TO SDF FOUND THE APU OIL REQUIRED SERVICING. APU OIL WAS SERVICED AND THE SYSTEM THEN CHECKED GOOD IAW DC-9 MM 49-10-0. LT GENERATOR SYS THEN OPERATIONALLY CHECKED GOOD IAW THE DC-9 MM 24-20-6. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)