What was found
DURING C-CHECK DISCOVERED CORROSION ON THE FLOORBEAM AT STATION 1030, RBL55 LOWER SURFACE UNDER TOP CAP. COMPLETED FLOORBEAM REPAIR AT STATION 1030, RBL 50-55 IAW SRM 53-10-8 FIGURE 3 PAGES 18 - 23.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK DISCOVERED CORROSION ON THE FLOORBEAM AT STATION 1030, RBL55 LOWER SURFACE UNDER TOP CAP. COMPLETED FLOORBEAM REPAIR AT STATION 1030, RBL 50-55 IAW SRM 53-10-8 FIGURE 3 PAGES 18 - 23.