What was found
DURING TAKEOFF ROLL, THE NR 2 ENGINE FIRE LIGHT ILLUMINATED. AFTER RETARDING THE POWER, THE LIGHT DISTINGUISHED. MAINTENANCE PERFORMED INSPECTION OF THE #2 ENGINE AND FOUND THAT THE AIR INTAKE HEATED LIP DUCT WAS DISCONNECTED. MAINTENANCE CONNECTED THE HEATED LIP DUCT.