Service difficulty report · Sensor · Emb ERJ190100IGW

Difficulty date
June 17, 2008
Submitted
July 30, 2008
Operation
Air carrier
Aircraft
N279JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000090
Aircraft time
2,762 hours, 1,628 cycles
Part
Sensor
Condition
Malfunctioned
Stage of operation
CL
How discovered
O
Nature of condition
B, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR RETURN TO DEPARTURE, AIR CONDITIONING VAPORS FOGGED UP FLIGHT DECK SO INTENSE WE WERE UNABLE TO SEE FLT INSTRUMENTS, ON CLIMB OUT OF 5000 RECYCLED PACK AND TURNING HEAT WAY UP VAPORS WENT AWAY. REMOVED AND REPLACED VENTURI DP SENSOR IAW FIM TASK 21-51-00-810-812. OPS CHECK OF AMS OK, NO FAULTS NOTED. REPLACED RECIR FILTERS AS PRECAUTION. (K)

More about the Emb ERJ 190-100 IGW