What was found
DURING TAXI, AFT RACK CARGO SMOKE INDICATION. RETURNED TO GATE. GROUND INSPECTION DETERMINED AFT RACK COOLING FAN FAILED. THE ITEM WAS PLACED ON MEL 25-22-03 D AND LATER THE FAN WAS REPLACED PER LTV MM 23-39-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING TAXI, AFT RACK CARGO SMOKE INDICATION. RETURNED TO GATE. GROUND INSPECTION DETERMINED AFT RACK COOLING FAN FAILED. THE ITEM WAS PLACED ON MEL 25-22-03 D AND LATER THE FAN WAS REPLACED PER LTV MM 23-39-00.