Service difficulty report · Processor · Emb ERJ190100IGW

Difficulty date
August 9, 2007
Submitted
August 10, 2007
Operation
Air carrier
Aircraft
N279JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000090
Aircraft time
111 hours, 73 cycles
Part
Processor
Part number
10010502009
Part serial
PR06115986
Condition
Failed
Location
Cabin Pressure
Part time
111 hours, 73 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 1090, CMH-JFK, AMS CTRL FAIL CAS MESSAGE APPLIED AT FL350 WITH CLOSURE OF BOTH BLEEDS AND PACKS ON THE ECS SYS PAGE. PRESSURES IN CABIN STARTED CLIMBING FROM 800-1000 FPM. AN EMERGENCY DESCENT WAS STARTED TO 10000 FEET. PRESSURE NEVER RETURNED. TROUBLESHOT SYS PER FIM TASK 21-00-00-810-805A. FOUND AMS FAILURE: FAULT CODES 21001510AM1 & 21001510AM2. CONTROL PROCESSOR AT FAULT. REMOVED AND REPLACED BOTH AMS CONTROLLER PROCESSORS AT SPDA 2 SLOTS 18 & 25 PER AMM 21-00-01. CHECK CONFIGURATION AND OPS CHECK NORMAL.