What was found
FLT 132 RSW-JFK ON SHORT FINAL, FAINT ELECTRICAL BURNING SMELL FOLLOWED BY VENT BLOWER FAULT ECAM, SELECTED OVRD, SMELL DISSIPATED. REMOVED AND REPLACED AVIONICS VENT FAN, OPS CHECK GOOD AS PER AMM 21-26-00. FAN TRIPPED, RESET FOUND BEARING BAD.