Service difficulty report · Detector · Emb ERJ190100IGW

Difficulty date
June 20, 2011
Submitted
June 21, 2011
Operation
Air carrier
Aircraft
N265JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000049
Aircraft time
13,366 hours, 7,940 cycles
Part
Detector
Condition
Defective
Location
Bleed Air Sys
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 1230 RDU-BOS, DIVERTED TO JFK DUE TO AIRCRAFT NOT BEING ABLE TO PRESSURIZE WITH NR 1 BLEED LEAK EICAS MESSAGE. THE AIRCRAFT HAD PACK 2 ALREADY IN MEL. THE CREW FOLLOWED QRH. THE TECHNICIAN PERFORMED FIM TASK 36-21-00-810-801A. ACCOMPLISHED RESET TEST OF BLEED ODS NVM IAW AMM 45-45-00-970-805A; PERFORMED VISUAL INSP OF BLEED DUCTS, CLAMPS & THERMAL INSULATION ON PYLON; NO EVIDENCE OF BLEED LEAK NOTED; REPLACED CERAMIC PINS ON THE LEAK DETECTOR 1&2 STATION 0; PERFORMED HIGH POWER-RUN & OPS CHECK OF BLEED SYS IAW 36-00-00; OPS NORMAL OK FOR CONT SYS.