Service difficulty report · Pump · Emb ERJ190100IGW

Difficulty date
March 19, 2012
Submitted
March 23, 2012
Operation
Air carrier
Aircraft
N328JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000422
Aircraft time
2,985 hours, 1,824 cycles
Part
Pump
Part number
5116404
Part serial
K1744
Condition
Leaking
Location
Nr 2
Part time
2,985 hours, 1,824 cycles
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 696 MCO-DCA, 100 MILES SOUTH OF RDU AT FL 370 CASS "HYD 2 LO QTY" APPEARED WITH 22% QTY REMAINING. QTY EVENTUALLY WENT TO ZERO / NO OTHER INDICATIONS. UPON GEAR EXTENSION CASS "HYD 2 ELEC PUMP FAIL" ILLUMINATED. GEAR AND FLAPS CAME DOWN NORMALLY, APPROACH AND LANDING 2 ROLL OUT WAS NORMAL. PRESS WAS NORMAL. FAULT CODE 29110050UT1, INSPECTED AND FOUND NR 2 HYD PUMP EXCESSIVE LEAK AT CASE FLANGE. REMOVED AND REPLACED NR 2 ENGINE DRIVEN PUMP IAW AMM 29-11-01. LEAK CHECK, NO FAULTS FOUND.