What was found
ON HEAVY MAINTENANCE CHECK, FOUND INTERNAL STRUCTURE BETWEEN FR 80 & 81, STRINGERS 28L & 27L CORRODED. BLENDED & REWORKED THE CORROSION DAMAGE, FABRICATED DOUBLER, SHIM, INSTALLED PARTS AND REPLACED FASTENERS. ALL WORK ACCOMPLISHED AND COMPLIED WITH EA E15-163-01.