Service difficulty report · Relay · Airbus A320232

Difficulty date
May 14, 2016
Submitted
May 18, 2016
Operation
Air carrier
Aircraft
N517JB
Make and model
Airbus A320232
Aircraft serial
1327
Aircraft time
61,475 hours, 22,649 cycles
Part
Relay
Condition
Failed
Location
Mlg
Stage of operation
AP
How discovered
O
Nature of condition
O
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY DECLARED. LANDING GEAR WOULD NOT EXTEND. PERFORMED L/G GRAVITY EXTENSION. WHEN LOWERING GEAR, GOT LANDING GEAR CONTROL ON LANDING GEAR DISPLAY; PERFORMED TSM 32-31-00-810-808-A. FOUND LANDING GEAR SYS ISOLATION VALVE NOT RECEIVING ANY POWER, 49GA. THIS STARTS THE LANDING GEAR DOOR PROCESS AND SINCE NO POWER, COULD NOT EXTEND GEAR IN AIR WHEN COMMANDED, PERFORMED WIRING CHECKS IAW ASM 32-31-07, SCH 07 AND 05. FOUND ISSUE WITH HERMETICAL RELAY, 62GA. REPLACED HERMETICAL RELAY. LANDING GEAR EXTENSION/RETRACTION FUNCTIONS NORMAL. PERFORMED SEVERAL CYCLES IAW AMM 32-31-00-720-002-A.