Service difficulty report · Solenoid Valve · Airbus A320232

Difficulty date
August 20, 2017
Submitted
August 23, 2017
Operation
Air carrier
Aircraft
N659JB
Make and model
Airbus A320232
Aircraft serial
3190
Aircraft time
41,350 hours, 14,605 cycles
Part
Solenoid Valve
Part number
733A000001
Part serial
0733A00LI001450
Condition
Failed
Location
Cockpit Temp
Part time
41,350 hours, 14,605 cycles
Stage of operation
CL
How discovered
O
Nature of condition
M, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK. THE TEMPS CONTINUED TO CLIMB. TROUBLESHOT AND FOUND LOW REGULATING PRESSURE IN THE NR 1 PACK, R & R THE FLOW CONTROL VALVE. FOUND A MISSING ACM LINE BLANKING PLUG, R & R THE PLUG. FOUND A CRACKED CONDENSOR, R & R THE CONDENSOR. PERFORMED A LEAK CHECK AND NO LEAKS NOTED. PERFORMED CFDS ZONE TEMP CONTROL TEST AND FUNCTIONAL TEST OF COCKPIT TEMPERATURE AND NO FAULTS FOUND.

More about the Airbus A320-232