What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE L2 DOOR SILL, FRAME FRAME 66. REMOVED THE CORROSION AND VERIFIED BEYOND 25% ALLOWABLE LIMITS IAW SRM 53-41-14-283-002. REMOVED AND REPLACED THE DOOR SILL IAW SRM 53-41-14, FIG 021.