What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR SUPPORT Y765 AFT OF FRAME 66. REMOVED THE CORROSION AND VERIFIED CORROSION WAS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-14-283-002. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 53-41-14, FIG 01.