DURING HEAVY MAINTENANCE, EMERGENCY LIGHTS INOPERATIVE IN LAVATORY D. TROUBLESHOT, FOUND 13WL EPSU BAD. REPLACED 13WL IAW AMM 33-51-38. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, EMERGENCY LIGHTS INOPERATIVE IN LAVATORY D. TROUBLESHOT, FOUND 13WL EPSU BAD. REPLACED 13WL IAW AMM 33-51-38. OPS CHECK GOOD.