Service difficulty report · Selector Valve · Airbus A320232

Difficulty date
July 5, 2021
Submitted
July 9, 2021
Operation
Air carrier
Aircraft
N612JB
Make and model
Airbus A320232
Aircraft serial
02247
Aircraft time
61,579 hours, 21,931 cycles
Part
Selector Valve
Part number
114079017
Part serial
CWDDDH6200
Condition
Failed
Location
Mlg
Part time
61,579 hours, 21,931 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 193, L/G LGCIU 2 FAULT AT GEAR RETRACTION DEPARTING EWR FOR STI DIVERTED TO JFK ;REF L/P 3112277 ITEM # & #2 L/G SELECTOR VALVE 40GA REPLACED IAW AMM 32-31-12 NORMAL EXTENSION AND RETRACTION TEST ACCOMPLISHED NO FAULTS NOTED. PFR AND PREVIOUS LEG GIVE L/G SEL VALVE 40GA R/R OF SEL VALVE @ 40GA IAW AMM 32-31-12 TEST REQUIRED PER SUBTASK 32-31-12-720-050A LEAK CHK REQ REF L/P 312277 ITEM # 2