What was found
FLT 1052, RSW-HPN. ENG 1 SPOOLED DOWN TO UNDER 50% N1 DURING CRZ FLT. LP VIBE 1.4, NO OTHER INDICATIONS. ENG 1 SPOOLED BACK UP AFTER 5 SECONDS TL'S DID NOT MOVE.; VERIFIED EEC SOFTWARE IAW AMM 76-00-00-050-004. CHECK CMC FOR FAULT EXCEEDANCES NO FAULTS FOUND PER FIM 72-00-00 810-022 . R&R EEC AS PRECAUTIONARY REF LOG PAGE 3204099 ITEM 1. ACCOMPLISHED # 1 ENG HIGH POWER ASSURANCE IAW CMM 72-00-00-760-047 TEST OK. NO FAULTS NOTED. ALL ENG PARAMETERS NORMAL