What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION: [CPCP FINDING] CORROSION ON SHEAR CLIP OVER FR 85 BTWN STGR 27-28 LH AT AFT CARGO COMPARTMENT; CORROSION ON SHEAR CLIP OVER FR 85 BETWEEN STGR 27-28 LH AT AFT CARGO COMPARTMENT WAS BLENDED OUT AND EVALUATED, THEREFORE IT IS OUT LIMITS. SHEAR CLIP WAS REPLACED FOR ONE NEW PER EMB 190 SRM 51-41-02 AND SRM 51-43-03, P/ N 170-66062-001 WAS REPLACED, ALL WORK ACCOMPLISHED ON TOMEX NRC 00145 (CLASSIFIED AS A MAJOR REPAIR)