What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION: [CPCP FINDING] CORROSION ON SHEAR CLIP OVER FR 85 BTWN STGR 27-28 RH AT AFT CARGO COMPARTMENT; ALL WORK ACCOMPLISHED ON TOMEX NRC 000144, CORROSION ON SHEAR CLIP LOCATED IN FR 85 BETWEEN STRG 27R/28R AT AFT CARGO COMPARTMENT WAS REMOVED AND EVALUATED, THEREFORE IT IS OUT LIMITS PER EMB190 SRM 51-12-01, SRM 51-10-03 AND SRM 51-75-16. SHEAR CLIP WAS REPLACED FOR A NEW SHEAR CLIP PER EMB190 SRM 51-41-01 AND SRM 51-41-02 (CLASSIFIED AS A MAJOR REPAIR)