What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION CPCP FINDING: CORROSION IN SHEAR CLIP LOCATED IN FR 87 BETWEEN STRG 27R/28R IN CF III INTERNAL STRUCTURE; ALL WORK ACCOMPLISHED ON TOMEX NRC 00075, CORROSION ON SHEAR CLIP LOCATED ON FR 87 BETWEEN STRG 27R/28R AT AFT CARGO COMPARTMENT WAS BLENDED OUT AND EVALUATED, THEREFORE IT IS OUT LIMITS PER EMB190 SRM 51-12-01, SRM 51-10--03 AND SRM 51-75-16. SHEAR CLIP WAS REPLACED FOR A NEW SHEAR CLIP PER EMB190 SRM 51-41-01 AND SRM 51-41-02. (CLASSIFIED AS A MAJOR REPAIR)