What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION CPCP FINDING: CORROSION ADJACENT TO FWD AND AFT LATCH FITTING LOCATED AT STRG 27R BETWEEN FR 77/80 IN AFT CARGO DOOR CUTOUT STRUCTURE; ALL WORK ACCOMPLISHED ON TOMEX NRC 00072, CORROSION ON BEAM-BAG DOOR LOCATED AT STRG 27R BETWEEN FR 77/80 IN AFT CARGO DOOR CUTOUT STRUCTURE WAS REMOVED AND EVALUATED, THEREFORE IT IS OUT LIMITS PER EMB190 SRM 51-12--01, SRM 51-10-03 AND SRM 53-23-11/AD54. BEAM-BAG DOOR WAS REPLACED FOR A NEW BEAM -BAG PER EMB 190 SRM 51-43-01, SRM 51--43-02, AND SRM 51-41-02. (CLASSIFIED AS A MAJOR REPAIR)