What was found
DURING HEAVY MAINTENANCE, CORROSION ON INBOARD LUG BUSHING HOUSING AT RH ELEVATOR HINGE 3; REF TOMX NR 00314 WO 1931: INBOARD LUG BUSHING HOUSING AT RH ELEVATOR HINGE 3 WAS REPAIRED PER EMB-190 SRM 55-21-00. REPAIR 51 AND EMB 190 SRM 51-29-00 WORK ACCOMPLISHED BY 200702030 INSP BY 200900620.