What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION CPCP FINDING: CORROSION ON FLOOR BEAM, LOCATED BTW FR84 AND -Y=330 AT PASSENGER FLOOR INTERNAL STRUCTURE (W2); CMOR: REPAIR PER EC NO: E22-494-01, ETI-190-22-599 REV 1, ETD2022-190-02094 REV.: A AND EMB190 SRM 53-23-10/REPAIR 54P. WORK ACCOMPLISHED ON TECH OPS W/O N328JB/1965/ E190/B5 CHECK NRC: 00262 TECH: 201532129 - FUERTE, JESUS ALEJANDRO 22/JUN/22 INSP: 200002656 - GUTIERREZ DIAZ, JESUS 22/JUN/22 (CONSIDERED AS A MAJOR REPAIR)