DURING HEAVY MAINTENANCE, INITIAL INSPECTION CPCP FINDING: CORROSION ON SUPPORT PANEL, LOCATED BTW FR88 - FR90 AND +Y=1100 AT PASSENGER FLOOR INTERNAL STRUCTURE (W2); CMOR: REPLACE PER EMB190 SRM 51-41-02, SRM 51-42-01 AND SRM 51-43-01. ACCOMPLISHED ON TECH OPS W/O N328JB/1965/E190/B5 CHECK NRC: 00261 TECH: 201532129 - FUERTE, JESUS ALEJANDRO 22/JUN/22 INSP: 201740577 - TRUJILLO CASTANEDA, RUTH ANDREA 22/JUN/22 (CONSIDERED AS A MAJOR REPAIR) (SUPPLEMENTAL INFORMATION ADDED TO CORRECT DISCREPANCY IN DESCRIPTION)