What was found
DURING HEAVY MAINTENANCE: CORROSION IN THE SHEAR CLIP LOCATED IN FR 86 AND BETWEEN STRG 27R/28R AT CF III INTERNAL STRUCTURE AFT CARGO COMPARTMENT; ALL WORK ACCOMPLISHED ON TOMEX NRC 00098, SHEAR CLIP LOCATED IN FR 86 AND BETWEEN STRG 27R/28R WAS REPLACED PER EMB-190 SRM 51-41-02, SRM 51-41-01 AND SRM 51-43-03. (CONSIDERED AS A MAOR REPAIR)