What was found
DURING HEAVY MAINTENANCE: CORROSION IN SHEAR CLIP LOCATED IN FR 84 AND BETWEEN STRG 27R/28R AT CF III INTERNAL STRUCTURE AFT CARGO COMPARTMENT; ALL WORK ACCOMPLISHED ON TOMEX NRC 00095: CORROSION IN SHEAR CLIP LOCATED IN FR 84 AND BETWEEN STRG 27R/28R AT CF III INTERNAL STRUCTURE THE AFT CARGO COMPARTMENT WAS REMOVED PER EMB-190 SRM 51-10-03, SRM 51-12-01, EVALUATED DUE TO EXCESSIVE CORROSION IS CLASSIFLICATED AS NON-REPAIRABLE DAMAGE AND WAS REPLACED PER EMB-190 SRM 51-10-02, EMB-190 SRM 51-41-02, SRM 51-41-01 AND DWG 170-66017-001 REV A. (CONSIDERED AS A MAOR REPAIR)