What was found
DURING HEAVY MAINTENANCE: CORROSION IN SHEAR CLIP LOCATED IN FR85 BETWEEN STRG 27R/28R AT CF III INTERNAL STRUCTURE; (RESOLVED ON W/O: 1214269 TASKCARD: NR-00019 ) CORROSION IN SHEAR CLIP LOCATED IN FR88 BETWEEN STRG 27R/28R AT CF III INTERNAL STRUCTURE WAS REMOVED AND EVALUATED OUT OF LIMITS PER EMB E190 SRM 51-12-01, SRM 51-10-03, SRM 51-75-16 AND REPLACED PER EMB 190 SRM 51-41-01 AND 51-41-02. ALL WORK ACCOMPLISHED ON TOMX WO# 2222, N/R #00079. ACCOMPLISHED BY TOMX TECH # 10000939. RII BY TOMX QC # 10001841.