What was found
DURING HEAVY MAINTENANCE: CORROSION IN SHEAR CLIP LOCATED IN FR76 BETWEEN STRG 28R/29R AT CF III INTERNAL STRUCTURE; (RESOLVED ON W/O: 1214269 TASKCARD: NR-00015 ) CORROSION ON SHEAR CLIP LOCATED IN FR 76 STRG 28R/29R AT CF III INTERNAL STRUCTURE WAS REMOVED PER EMB-190 SRM 51-10-03, SRM 51-12-01 AND EVALUATED OUT OF LIMITS PER EMB 190 SRM 51-75-16. THEREFORE WAS REPLACED PER EMB 190 SRM 51-41-01 AND SRM 51-41-02. ALL WORK ACCOMPLISHED ON TOMX WO # 2222, N/R # 00091. ACCOMPLISHED BY TOMX TECH # 10000939. RII BY TOMX # 69707.