What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 AT FWD GALLEY AREA (CRACK INDICATION FOUND ON FRAME 16LH DOOR STOP FITTING 7 UPPER INBOARD HOLE, CRACK DIRECTION 1 OCLOCK AND CRACK DEPTH 0.152 INCH ); (RESOLVED ON W/O: 1301529 TASKCARD: NR-00017) REF AE W/O# 2024-49/1. N/R# 2024-218392. REMOVED AND REPLACED INTERCOSTAL FITTING AND FASTENERS LOCATED FR16 LH DOOR STOP FITTING 7 IAW A320 SRM 51-42-11 AND DRAWING D53112300.