LANDING GEAR FAILED TO EXTEND DUE TO INTERNAL FAILURE OF ELECTRIC GEAR MOTOR. REPLACED MOTOR AND SYSTEM OPS CHECKS GOOD. ALTERNATOR OUT LIGHT PROVED TO BE BROKEN WIRE ON IN-LINE FUSE FOR INDICATOR. REPAIRED WIRE AND OPS CHECKS OK. ALSO REPLACED ONE ACFT BATTERY WITH NEW. RUN-UP FOR ELECTRICAL SYSTEM OPS CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.