What was found
ACFT WAS STRUCK BY LIGHTNING, MIDFLIGHT AT 13,000 FT WHILE EN-ROUTE. IMMEDIATELY AFTER THE STRIKE COCKPIT BEGAN TO ODOR OF ELECTRICAL SMOKE. CREW DONNED 02 MASKS AND DECLARED AN EMERGENCY. LANDING WAS UNEVENTFUL. MX ACCOMPLISHED A LIGHTNING STRIKE INSPECTION AND REPLACED THE RADOME ASSY, BOTH COMM ANTENNAS, BOTH NAV ANTENNAS, LOWER FAIRING PANEL, LT STRAKE, TAIL STRINGER AND RUDDER TIP CAP. A SUCCESSFUL OPS CHECK FLIGHT WAS ACCOMPLISHED. ACFT WAS RETURNED TO SERVICE.