What was found
DURING CHECK-C MAINT FOUND CORROSION ON RH TIE DOWN TRACK, OTBD FLANGE, STA 1212 TO 1322. REMOVED CORRODED TRACK. FABRICATED NEW TRACK AND PAINTED TRACK. INSTALLED NEW TRACK PER SPM 6-70-01, PAGE 2 AND 3. FASTENER INSTALLATION PER 51-30 AND 51-10-4.