What was found
DURING CHECK-C MAINT THE TOP SURFACE JUST AFT OF L/E AND 6 FT OTBD OF FUSELAGE, FOUND PATCH DELAMINATED WITH RAGGED EXPOSED EDGE. INSTALLED 4 .5 INCH DIAMETER METAL TO METAL HOT BOND REPAIR ON UPPER LEFT HORIZONTAL STABILIZER PANEL PER SRM 55-10-01, PAGE 1, AND 51-70-10 PAGE 52. PRIMER, SANDED, AND MATCHED PAINT.