Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026011264386Shield · corrodedAFT CARGO DOOR AFT SHIELD HAS CORROSION. GROUNDED - YES. REMOVED DAMAGE ON AFT SHIELD FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15-1A-1, REMOVED AND REPLACED IAW B737-800, SRM 51-40-05-0G-0, SRM 51-40-02-0G-0W: 1.5 OT: 0.050" RT: 0.042" L: 2.5" D: 0.008".SDR ASAA2026011264385Sidewall Support · corrodedREMOVED CORROSION FOUND TO BE OUT OF LIMITS, REPAIRED FLOOR BEAM IAW B737-800 SRM 53-70-51-2R-0W: 1" O: .150 R: .073 L: 1.5" D: .077. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED IAW B737-800 SRM 51-40-02-0G AND 53-00-07-1A-1WSDR UIEA2026021620048Proximity Sensor · faultedGEAR TILT STATUS MESSAGE. FOUND MX MSG 32713 & 32673. FOLLOWED FIM 32-61 TASK 883 & TASK 863. REPLACED WIRE W1174-225/226 AND WIRE 1174-327 /228 IAW WDM 32-61-16 & 32-61-25. REMOVED AND REPLACED PRIMARY & ALTERNATE TRUCK TILT PROX SENSORS IAW AMM 32-61-12. PSDR SWAA2026021360792Access Panel · delaminatedDELAMINATED ACCESS PANEL 644BB AT RT WING. REPAIRED THE ACCESS PANEL 644BB IAW SRM 57-53-70-2R-5, REPAIR 5.SDR SWAA2026021260593Stub Frame · crackedA CRACK INDICATION ON THE STUB FRAME, BTWN BS 294.5 - 296.5, S8R - S9R AT THE FWD GALLEY DOOR AREA. REPLACED THE STUB FRAME IAW SRM 51-40-02, SRM 51-10-02, PARAGRAPH 9, & DWG 141A8370, SHEET 9, & SHEET 11, DWG 141A3310, SHEET 43, REV -, & DWG 141A8380, SHEET SDR SWAA2026021260791Gusset · crackedCRACKED GUSSET, BS 500D, S19R IN THE FWD CARGO BAY. REPLACED THE GUSSET AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 143A7902, SHEET 174, REV -.SDR SWAA2026021260595Floor Support · crackedCRACKED FLOOR SUPPORT, BS 695, BL0. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 273A9110, SHEET 6, REV A.SDR SWAA2026021260597Crossbeam · crackedCRACKED CROSSBEAM, BS 540, BL 0 - LBL 24.75. REMOVED PROTECTIVE TREATMENT & PERFORMED GVI AND DID NOT FIND ADDITIONAL DAMAGE ON AREA IAW AMM 51-21-11-150-801, REPLACED THE CROSSBEAM AND FASTENERS IAW SRM 51-10-02, ITEM 9, AND DWG 143A0060, SHEET 46, REV -SDR SWAA2026021270218Crossbeam · crackedCRACKED CROSSBEAM, BS 540, BL0 - LBL 24.75. REMOVED PROTECTIVE TREATMENT AND PERFORMED GVI & DID NOT FIND ADDITIONAL DAMAGE IN AREA IAW AMM 51-21-11-150-801, REPLACED THE CROSSBEAM AND FASTENERS IAW SRM 51-10-02 ITEM 9, & DWG 143A0060, SHEET 46, REV -.SDR SWAA2026021260591Angle · crackedCRACKED FLOOR SUPPORT, BS 695, RBL24.75. REPLACED THE FLOOR SUPPPORT IAW SRM 51-40-02, & DWG 273A9110, SHEET 6, REV A.SDR SWAA2026021260594Angle · crackedCRACKED FLOOR SUPPORT, BS 695, LBL24.75. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 273A9110, SHEET 6, REV A.SDR SWAA2026021260598Crossbeam · crackedCRACKED CROSSBEAM, BS 540, BL0 - RBL 24.75. REPLACED THE CROSSBEAM & FASTENERS IAW SRM 51-40-02, SRM 51-10-02, AND DWG 143A0060, SHEET 46, REV -.SDR ASAA2026011264271Support Angle · corrodedAFT CARGO STA 727J R/H SUPPORT ANGLE HAS CORROSION STR 26. GROUNDED - YES. REMOVED CORROSION ON SUPPORT ANGLE, AFT CARGO STA 727J RH STR26, FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED SUPPORT ANGLE SPLICE IAW B737-800 SRM 51-40-02-0G-0, SRM 51-40-05-0G-0, SDR ASAA2026011264241Intercostal · corrodedAFT CARGO INTERCOSTAL BS 747-767 RBL 20 CORRODED. GROUNDED - YES. REMOVED AND REPLACED INTERCOSTAL ON AFT CARGO BTW BS 747-767 RBL 20 IAW SRM 51-40-05-0G-0. SRM 51-40-02-0G-0.SDR ASAA2026011264240Transition Panel · corrodedFWD CARGO LEFT TRANSITION PANEL HAS AREAS OF CORROSION FROM BS 500B TO 500I. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, R & R IAW SRM 53-00-53-2R-5, & 53-00-53-1-2.SDR ASAA2026011264239Transition Panel · corrodedFWD CARGO RT TRANSITION HAS AREAS OF CORROSION FROM STA 500A TO 500L. GROUNDED - YES. REMOVED CORROSION ON TRANSITION, FWD CARGO FROM BS 500A TO 500 L, RT SIDE FOUND TO BE OUT OF LIMITS. R & R IAW SRM 53-00-53-1A-2, & SRM 53-00-53-2R-5, REPAIR 5.SDR IPXA2026021059710Skin · bulgedRIGHT WING T/E UPPER FIXED PANEL OTBD OF OTBD FLAP, T/E WEDGE HAS SPOTS OF BULGING SKIN POSSIBLY CORROSION, FROM 1ST TO 3RD STATIC WICK. INSTALLED NEW PART SECTION PANEL TRAILING EDGE RH WING UPPER, IAW SRM 51-40-21.SDR SWAA2026020660585Web · crackedCRACK ON WEB - INTERCOSTAL BTW BS 294.5 - 303.9, STRINGER 16L IN THE FWD GALLEY & LAV. PERFORMED MAJOR REPAIR ON WEB-INTERCOSTAL LOCATED IAW EA 26-153-00170-WIP1.SDR SWAA2026020660566Bulb · burned outCABIN OVERWING EMERGENCY LIGHTS HAVE BURNED OUT LIGHT BULBS. PERFORMED OPS TEST OF CABIN OVERWING EMERGENCY LIGHTS IAW AMM 33-51-00-710-801, TEST PASSED.SDR SWAA2026020660584Support Angle · crackedCRACKED SUPPORT ANGLE, BS 500D, S28L IN THE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02-0G-0, AND DWG 143A7902, SHEET 1, REV E.SDR IPXA2026011963930Seat Track · corrodedCAP SEAT TRACKS HAVE EVIDENCE OF CORROSION (AFT I/B EXFOLIATED) MARKED AREAS. REMOVED CORROSION LOCATED ON MAIN DECK FLOOR SHEAR UNDER SEAT TRACK. LBL13.0 AND 20'' UPPER STA278.0 O.T: .050''. MAT LOSS:0.035''. L:0.7'', W:0.7'' REWORK WAS FOUND OUT OF LIMITS ISDR IPXA2026020462981Stringer · corrodedFUSELAGE SKIN IS BULDGING AROUND TWO FASTNER HEADS, JUST FORWARD OF THE AFT LOWER FUSELAGE MAJOR REPAIR AT AFT VHF ANTENNA. REMOVED 3 BULDGING RIVETS FORWARD OF THE AFT LOWER FUSELAGE MAJOR DOUBLER REPAIR AT STATION 1460 AND FRAME 1480 OF AFT VHF ANTENNA, NOSDR IPXA2026013069167Tee Angle · corrodedWING TO BODY FAIRING STRUCTURE LOWER T-CHORD EXFOLIATED AND WITH MULTIPLE SPOTS OF HEAVY CORROSION FROM BS 1180 TO 1240 AT RBL 57.50. DOT 21-40. EVALUATED TEE FITTING BETWEEN STA 1180-1240 AT RBL 57.5 AND FOUND TO BE EXFLOIATED WITH 100% MATERIAL LOSS AND ISSDR IPXA2026012869037Tee Fitting · corrodedWING TO BODY FAIRING STRUCTURE UPPER TEE FITTING EXFOLIATED AND WITH MULTIPLE SPOTS OF HEAVY CORROSION FROM BS 1180 TO BS 1240, RBL 57.50. REMOVED AFT WTB PANEL 198LR TO FOM IAW AMM 53-66-01-004-001. INSTALLED THE TEE FITTING IAW SRM 51-40-02.SDR IPXA2026012868936Channel · corrodedWING TO BODY FAIRING SUPPORT STRUCTURE WITH EXFOLIATED CORROSION AT BS 1219 RBL 6. INSTALLED NEW CHANNEL, 2EA SUPPORT PLATES, 1EA ANGLE, IN WING TO BODY, BS 1219 RBL 6, IAW B757 SRM 51-40-02-0G-0.SDR IPXA2026012869140Tee Fitting · corrodedWING TO BODY FAIRING STRUCTURE, VERTICAL T-FITTING EXFOLIATED AT LWR END AT BS 1200 RBL 57.50. INSTALLED T-FITTING IAW SRM 51-40-02.SDR SWAA2026012860575Access Panel · crackedCRACKED ACCESS PANEL 551GB, TRAILING EDGE LT WING. REPAIRED THE ACCESS PANEL 551GB IAW SRM 51-70-05-2R-10, REPAIR 10.SDR SWAA2026012860649Skin · bulgedNUMBER 2 LE SLAT HAD BULGING SKIN JUST ABOVE THE LE AT THE ACTUATOR. R & R THE NR 1 SLAT IAW AMM 27-81-00.SDR IPXA2026012369147Tee Fitting · corrodedRIGHT WW EXTERNAL STRUCTURE BETWEEN BS 1040 - 1060 INTERCOSTAL DELAMINATED. INSTALLED NEW T-FITTING, IAW SRM 51-40-02-0G-0.SDR SWAA2026012760380Access Panel · delaminatedACCESS PANEL 191CL HAS SMALL AREA OF DELAMINATION ON OUTSIDE OF PANEL APROX 22" FROM FWD END AND 15" FROM UPPER END. REMOVED THE AREA OF DELAMINATION IAW SRM 51-70-05-0G-0. ACCOMPLISHED A REPAIR TO AREA IAW SRM 51-70-05-2R-1.SDR AALA202601271318Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663, LBL 18. REPAIRED ANGLE PER SRM 57-10-10-2R-5 AND AARD 51-00-05-1.SDR IPXA2026012769147Intercostal · delaminatedRIGHT W/W EXTERNAL STRUCTURE BETWEEN STA 1040 TO 1060 INTERCOSTAL WITH DELAMINATION DOT 07-060 REVIEWEDSDR AALA202601235702Wire · brokenAIRCRAFT WAS NOT GROUNDED: SEAT 1C WALL MOUNTED EMERGENCY LIGHT INOPERATIVE. **SUPPLEMENTAL REPORT FOR AALA202601165702 SUBMITTED 1/16/2026 BY TUL: MAINTENANCE FOUND SEAT MOUNTED EMERGENCY LIGHT AT 1C INOPERATIVE INSTEAD OF THE WALL MOUNTED EMERGENCY LIGHT. MASDR SWAA2026012260576Housing · brokenLEFT FWD OVER WING EXIT LINER EXIT LIGHT HOUSING IS BROKEN. REMOVED AND REPLACED THE LIGHT HOUSING IAW SOPM 20-50-01.SDR AALA202601225243Fseu · faultyAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: THE FLAPS DID NOT EXTEND PAST 5, THIS IS THE THIRD CONSECUTIVE TIME THAT THIS ISSUE HAPPENED. AIRCRAFT EMERGENCY LANDED INTO ORD SAFELY. ACCOPLISHED FLAP POSITION TRANSMITTER DISAGREE PROBLEM FAULT ISOLASDR CALA2026012113128Engine · faultedFL320 EPR ON RT ENGINE WENT TO 0. FUEL FLOW 0. N1 & N2 AND EGT NORMAL. DESENDED FL260 REF LOGPAGES 7585195, 7585208, 7585331, 7585968 DUE TO ENG 2 EXCEEDENCES AND DAMAGE FOUND, REPLACED ENG 2 PER JOB CARD 76-0572-8-0015.SDR FDEA202601120064Panel · crackedNDT INSP, LT CENTER BOX REAR SPAR FR47 FWD FITTING RIB 1 HOLE G FOUND A CRACK SIGNAL. COMPLIED WITH EA 6-5710-T0386165 REPAIRED THE CRACKED HOLE "G" AT LH CENTER WING BOX REAR SPAR FR47 FWD FITTING RIB1. MAJOR REPAIR IAW FEDEX GMM 6-2-100. SEE WRI 57107SDR DALA2026011700399Door · openDURING BOARDING, OVERHEAD PANEL IN ROW 23ABC WHICH SERCURES PAX O2 MASK FELL DOWN. DEFERRED SEAT ROW 23ABC O2 MASK PER A320 MEL 35-21-01B. M PROCEDURES C/W PLACARD INSTALLED. R & R OVERHEAD O2 PANEL PER CMM 25-28-02. DOOR STAYS CLOSED. PERFORMED OPS CHECK PERSDR AALA202601165243Flap System · abnormalAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: THE FLAPS DID NOT EXTEND PAST 5, THIS IS THE THIRD CONSECUTIVE TIME THAT THIS ISSUE HAPPENED. AIRCRAFT EMERGENCY LANDED INTO ORD SAFELY. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).SDR ASAA2026011263751Light · inoperativeEXTERNAL EMERGENCY EXIT LIGHT NEXT TO R2 DOOR INOPERATIVE. GROUNDED - YES. TRASFERRED DISCREPANCY TO AAR MIG-5 W/O 1023813 9600-0003 S/N: OK455561.SDR UIEA2026011200013Seal · damagedFLIGHT DECK PBE SEAL DAMAGED. REPLACED PBE PER AMM 25-64-00. OPS CHK OK.SDR UIEA2026011200014Extinguisher · damagedFIRE EXT DAMAGED AT 17F. >REINSTALLED BOTTLE PER EO 6725A348. NO FURTHER DEFECTS NOTED.SDR FDEA202601120048Frame · crackedNDT INSP - RT CENTER BOX REAR SPAR FR47 FWD FITTING RIB1 HOLE "C" FOUND CRACK SIGNAL. COMPLIED WITH EA 6-5710-T0386164 REPAIRED THE CRACKED CENTER WING BOX REAR SPAR RHS FR47 FWD FITTING RIB1 HOLE "C". TITLE: WINGS - BASIC WING STRUCTURE - FR47 RH REAR SPSDR AALA202601165702Light · inoperativeAIRCRAFT WAS NOT GROUNDED: SEAT 1C WALL MOUNTED EMERGENCY LIGHT INOPERATIVE. (OPEN)SDR CALA2026011613011Skin · damagedPOSSIBLE LIGHTING STRIKE ON EXT FUSE FASTENER AT STA 243.7, 10" BELOW STRINGER 16RREMOVED EXISTING FASTENERS COMMON TO REPAIR DOUBLER. ACCOMPLISHED INSP IAW SRM 53-10-01-2R-8 REPAIR STEPS 4.H.(3) AND (4). REMOVED FASTNER HOLES & COUNTERSINKS IAW SRM 53-10-0SDR CALA2026011612989Skin · damagedAFT CARGO DOOR REQUIRES NEW SKIN, REMOVED AND REPLACED AFT CARGO DOOR OUTER SKIN IAW SRM 52-30-01-2R-3. ALL WORK ACCOMPLISHED ON AAR NR 9280189. REMOVED AND REPLACED OUTER SKIN IAW SRM 52-30-01-2R-3 REP 3, CMM 52-31-14, AND DWG 146A6110 REV C.SDR SWAA2026011560606Rib · buckledRIGHT HORIZONTAL STABILIZER INSPAR RIBS DAMAGED REF TTG8Q019UD05. RT HORIZ STAB WILL BE REPLACED ON FAULT TTG8Q019XCM3.;[02] RT HORIZ STAB WILL BE REPLACED ON FAULT TTG8Q019XCM3.SDR SWAA2026011561698Lens · looseFWD GALLEY OVERHEAD LIGHT ANNUNCIATOR LENS LOOSE INDICATOR LIGHTS WORKS NORMAL AT THIS TIME. OK TO CONTINUE IAW MEL 25-10-01, SP-1B, 301789. LENS COVER SECURED IN PLACE. REPLACED FWD GALLEY EMERGENCY EXIT SIGN ASSY IAW AMM 33-51-01. OPS CHECKED OKAY.SDR DALA2026011500360Repair · damagedON R1 DOOR AFT LWR SHEET REPAIR FOUND ONE RIVET BUCKTAIL ISN'T CENTER AND OFF TO ONE SIDE. ALSO FOUND SEALANT MISSING FOR SEAL RETAINER. APPLIED SEALANT ON FWD CHANNEL CORNER ON FWD PAX DOOR PER A319 SRM 52-10. REMOVED TWO RIVETS WITH POOR QUALITY BUCKTAILS RSDR DALA2026011500359Floor Support · corrodedAFT CABIN LONGITUDINAL BEAM AT Y1292 HAS CORROSION BETWEEN FR67 AND FR68. FLOOR SUPPORT IN AFT CABIN AT Y1292 AND BETWEEN FR67-68 HAD CORROSION REMOVED AND EVALUATED DAMAGE, FOUND DAMAGE TO BE OUT OF LIMITS. REMOVED AND REPLACED DAMAGED FLOOR SUPPORT IAW SRM