Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR I5PA2025050568803Controller · failedFLT NR: MGE 411. ESI - LH ENG BLEED FLUCTUATING ON DECENT. REVERSE FLOW CHECK CONTROLLER (RFCC) FAILED DURING PNEUMATIC HEALTH CHECK. R/R RFCC PER AMM.SDR DALA2025050603512Floor Support · corrodedCORROSION ON PASSENGER CABIN FLOOR SUPPORTS (2 EA) BETWEEN Y=148 - 200, X=7 AND X=-7. SUMMARY OF NRC 00637: CORROSION LEVEL 2. FLOOR SUPPORTS (2 EA) BETWEEN Y=148 - 200, X=7 AND X=-7, WERE FABRICATED PER DWG 9936534 REV BW, AND REPLACED PER B717-200 SRM 51-41-SDR SWAA2025050667644Slide · dislodgedFWD ENTRY SLIDE CAME OUT OF DOOR CONTAINER DURING DEPLANEMENT. DID NOT DEPLOY<[01] REMOVED & REPLACED L1 DOOR SLIDE REF AMM 25-66-01<BR>OPS CHECKED GOODSDR SWIA202505060005Door · warning messageSERVICE DOOR CAUTION MESSAGE PASSING THROUGH 10,000. PRESSURE STAYED NORMAL. DOORS PAGE SHOWED OUTER HANDLE, MESSAGE DISAPPEARED AND REAPPEARED MULTIPLE TIMES, MEL 52-70-5CAT C DUE DATE IS 05/15/2025"SMOD APPROVAL REQUIRED BEFORE RTS AFTER COMPLETION." (FLIGHTSDR IPXA2025050512703Skin · deformedNR 2 PYLON FWD FAIRING LH AND RH SIDE SUPPORT ANGLES (P/N A54612200200/201)DEFORMED FWD OF RIB J4. DOT# 110-99 JP-110SDR DALA2025050603511Tire · puncturedSHIP 3503 -MISC/DE- DUE TO NUMBER SIX TIRE DEFLATED AFTER TAKEOFF. CORRECTIVE ACTION: FOUND TIRE PUNCTURED FROM FOD. REPLACED NUMBER SIX TIRE AND BRAKE ALONG WITH NUMBER FIVE TIRE. (LP# 7145990)SDR HALA20250506125Seal · brokenETOPS - ENG 2 OIL CAP SEAL BROKEN. REMOVED & REPLACED ENG 2 OIL CAP SEAL IAW AMM 79-11-42, OPS CHECK GOOD. OK FOR SVC.SDR HALA20250506124Fire Loop · faultedETOPS - SPURIOUS ENG1 FIRE LOOP B ECAM. ECAM ILLUMINATED 4 TIMES DURING FLIGHT. REMOVED AND REPLACED ENG1 AGB LOOP B PER AMM 26-12-17, PERFORMED FDU BITE TEST PER AMM 26-12-00 TEST OK. A/C OK FOR SVC.SDR DALA2025050603475Floor Panel · corroded***CORROSION*** ALONG FWD EDGE, AFT INBOARD CORNER AND AFT EDGE OF ASD ENTRY FLOOR PANEL 242MRF. REMOVED AND REPLACED FLOOR PANEL 242MRF IAW A220 AMP BD500- A-J53-00-47-14AAA-520A-A AND A220 AMP BD500-A-J53-62-33-02AAA- 720A-A. (LP# 0950393)SDR AALA202505067378Battery Pack · dischargedAIRCRAFT WAS NOT GROUNDED: POWER SUPPLY AT BS 310 FAILED EMERGENCY LIGHT BATTERY PACK CAPACITY FUNCTIONAL CHECK. REMOVED AND REPLACED POWER SUPPLY, OPERTIONAL CHECK GOOD. PER AMM 33-51-06.SDR AALA202505063627Door · draggingAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR DIFFICULT TO OPEN AND CLOSE. RESECURED TRIM ON BOTTOM OF DOOR. WAS DRAGGING ON THRESHOLD. OPERTIONAL CHECK GOOD.SDR AALA202505069846Tire · blownAIRCRAFT WAS GROUNDED: NUMBER 3 MAIN LANDING GEAR TIRE BLOWN ON LANDING. REMOVED AND REPLACED NUMBER 3 MLG TIRE AND WHEEL ASSEMBLY. PER MM 32-45-11.SDR AALA202505067472Slide · unpackedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTANDENT REPORT R1 DOOR DIFFICULT TO ARM AND DISARM SLIDE. REMOVED AND REPACKED R1 DOOR ESCAPE SLIDE. PER AMM 26-66-01. ARMING AND DISARMING OF DOOR OPERTIONAL CHECK GOOD.SDR AALA202505060928Light · inoperativeAIRCRAFT WAS NOT GROUNDED: FOUND EMERG. LIGHT ON G3 GALLEY. (ON COMPT 371 OUTBOARD WALL) DAMAGED, INOP. MAINTENANCE REPLACED EMER LIGHT ASSY AT G3 GALLEY AND TESTED OK IAW AMM 33-51-00.SDR FDEA202505050717Girt Bar · lack of lubeR1 DOOR "SLIDE" ARMED LIGHT WILL NOT ILLIMUNATE. RELAMPED NO HELP. ARM LEVER DOES NOT APPEAR TO MOVE FULL TRAVEL WHEN ARMING AND PRESUME DOOR IS NOT ARMED. COMPLIED WITH INSPECTION/TEST GIRT BAR HANDLING IN REF TO AMM 52-11-25-5. COMPLIED WITH LUBE OF GSDR FDEA202505050716Lamp · failedR1 DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOP. RELAMPED IAW ABOVE REF OPS CHK SERVICEABLE. OK TO CONTINUE.SDR AALA202505063277Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L3 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202505065268Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202505066733Battery · no testAIRCRAFT IN BASE MAINTENANCE: FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 10WL DISPLAYED DURING SYSTEM TEST. REPLACED PASSENGER / CREW DOOR 831 SLIDE RAFT PER AMM 25-62-44 (AALA202505060987) AND REPLACED THE BATTERY FOR EMERGENCY POWER SUPPLY 10WL PER AMM 3SDR AALA202505061551Structure · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERNAL STRUCTURE SECTION CONNECTION AT FR 66 AND S23L. REPLACED SECTION CONNECTION PER SRM 51-72-11.SDR AALA202505062074Structure · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERNAL STRUCTURE SECTION CONNECTION AT FR 66 AND S23R. REPLACED SECTION CONNECTION PER SRM 51-72-11.SDR AALA202505061544Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202505060987Slide Raft · no testAIRCRAFT IN BASE MAINTENANCE: FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 10WL DISPLAYED DURING SYSTEM TEST. REPLACED PASSENGER / CREW DOOR 831 SLIDE RAFT PER AMM 25-62-44 (AALA202505060987) AND REPLACED THE BATTERY FOR EMERGENCY POWER SUPPLY 10WL PER AMM 3SDR REXA2025050600558Floor Support · corrodedFABRICATION OF LBL 9 FLOOR BEAM P/N MM670-35301-005 IS REQUIRED FOR FLOOR BEAM REPLACEMENT ON MWC HN00233441,S/N 898. FABRICATED FLOOR BEAM P/N MM670-35301-005 FOR LBL 9 FROM FS 977 - FS 1098 (MADE FROM 7075-T73511 PO# 5-37778) IAW CRJ 700 SRM 51-24-36-001-0SDR REXA2025050600557Stringer Splice · corrodedSTRINGER SPLICE AT STGR 21 F.S. 333 IS CORRODED INSTALLED NEW SERVICEABLE STRING SPLICE PN: SH670-31197-1 FOR STR 21R AT FS 333 IAW CRJ700 SRM 51-42-06-001-001-A01.SDR SIMA20250505001Module · failedSTEER FAIL ON TAKEOFF ROLL. ONCE GEAR EXTENDED ON ARRIVAL, EICAS AMBER STEER FAIL MESSAGE CAME BACK. CB RESET WORKED FOR ABOUT 30 SECONDS. CB METHOD ATTEMPTED 3 TIMES. STEER FAIL MESSAGE CONT TO COME ON. EMERGENCY DECLARED. "TRANSFERRED TO NRWC 040-DFW-04570" SDR SIMA20250505003Seat Track · corrodedCORROSION ON RH SEAT TRACK AT FR17 & Y +10.75? AS MARKED. (LEVEL 2 CORROSION) (MAJOR REPAIR) BLENDED CORROSION ON RH SEAT TRACK AT FR17 & Y +10.75" PER EMB E-175 SRM 51-10-03. BLEND MEASURES L=1.6"" W=.1.5" H=- .72. BLEND IS FOUND TO BE OUT OF LIMITS PER EMB ESDR SIMA20250505005Light · intermittent2 AFT EMERGENCY EXIT SIGNS INOP OPS CHECKED EMERGENCY EXIT LIGHT SYSTEM IAW AMM 33-50-00-710-801-A. ALL EMERGENCY EXIT LIGHTS OPERATED, NO DEFECTS NOTED.SDR SIMA20250505002Shunt · faultedBLEED 1 OVRPRSS. ATC DECLARED EMERGENCY. RETURN TO DFW. ACCOMPLISH PER ERJ WC 36-11-03-001. NAPRSOV VALVE FILTER CLEANING OF NACELLE PRESSURE-REGULATING SHUTOFF-VALVE FILTER BY ULTRASONIC METHOD. OPC BLEED 1 FAIL AND BLEED 1 OVERPRESSURE GOOD IAW AMM 36-11-00 SDR SIMA20250505004Floorbeam · corrodedCROSSBEAM AT FR 17 CORRODED JUST INBD OF CENTER FLOOR BEAM UNDER FLOORBOARD 225ALF. (LEVEL 2 CORROSION) (MAJOR REPAIR) PERMANENTLY REPAIRED IAW ERS-EJ-53MR-4564 PTB.SDR HNAA2025050600303Warning Message · illuminatedE1 REV DISAGREE ON EICAS TAKEOFF ROLL. ENG 1 OR 2 REV DISAGREE MESSAGES RAN T/RS CND. OPS CHK GOOD. PINS INSTALLED IN ORINGINAL POSITION. OK FOR SERVICE AT THIS TIME.SDR HNAA2025050600302Unknown · odorCREW REPORTS FUMES IN FLIGHT DECK AT GATE. UPON ARRIVAL NO FUME SMELLED IN COCKPIT WITH NO CHANGE OTHER THAN APU ON/OFF. RAN APU WITH PACKS 1/2 IN VARIOUS CONFIGURATIONS. WPU ON AND PACKS ON/OFF TRIED TO LOCATE ANY CUPRIT OF FUMES NONE LOCATED. FLIGHT DECK CSDR 2A6R2025050572703Splice Plate · chafedCHAFE DAMAGE WAS DISCOVERED ON THE TRANSMISSION DECK SUPPORT BEAM AFT SPLICE PLATE (PN: B533K3265-201) AT FS 4,963, MID SPLICE PLATE (PN: B533K3193-201) AND LH SUPPORT BEAM CAP (PN: B533K3202-201) AT FS 4,615, AND ON THE FORWARD SPLICE PLATE (PN: B533K3192-201SDR CALA2025050604509Window Frame · crackedDURING WINDOW CLEAN FOUND CRACK ON R3 WINDOW FRAME, FORWARD LOWER CORNER.PHOTO ADDED. CRACK EXTENSE THE LENGTH OF POST 3, 2ND FASTENER UP FROM BOTTOM, WINDOW POST IS OUT OF LIMITS PER SRM 56-10-02 -1A-3 STEP 4.A.1 DETAILS A,B AND D . MADE CUT IN RH DOOR POST RSDR CALA2025050604508Skin · damagedREF L/P4559461. RH FUSELAGE DAMAGE BETWEEN STA. 609+240 AND 632 ABOVE STR23L.COMPLIED WITH STEPS 1 THRU 4 AND 6A IN REF TO AVO14615 COMPLIED WITH STEP 5A-B OF AVO14615 NO OTHER DAMAGE NOTED AT THIS TIME COMPLIED WITH STEPS 6A-C OF AVO14615, .5"X.5" GRID ON INTSDR CALA2025050604506Slide · out of position2L EMERRGENCY SLIDE RESTING ON FLOOR REMOVED REPACK AND REINSTALLED SLIDE 2L IAW AMM 25-66-01-400-804. ADD EMP: U345588 COMPLIED WITH RII STEPS FOR REINSTALLATION OF 2L EMERGENCY SLIDE IAW AMM 25-66-01-400-804. NO FURTHER DEFECTS NOTED AT THIS MOMENT.SDR CALA2025050604505Slide · out of position1R EMERGENCY SLIDE RESTING ON FLOOR OF GALLEY REMOVED SLIDE PACK, REPACKED SLACK AND REINSTALLED R1 EMERGENCY SLIDE IAW AMM 25-66-01-400-804 ADD EMP: U332682 COMPLIED WITH RII STEPS FOR R1 EMERGENCY SLIDE REINSTALLATION IAW AMM 25-66-01. NO FURTHER DEFECTS NOTSDR CALA2025050604504Slide · noneDOOR 2L EMERGENCY SLIDE PRESSURE OUT OF LIMIT DOOR 2L SLIDE PACK INFLATION CYLINDER WITHIN LIMITS PER AMM TASK 25-66-01-200-801. WITHIN 1 NEEDLE WIDTH TO THE RIGHT OF GREEN BAND. OKAY FOR SERVICE.SDR CALA2025050604494Smoke Detector · false activationECAM.SMOKE LAVATORY S MOKE ATTANDENT INFO PAN EL INDIC. LAV H PERFORMED TSM 26-17-00-810-804-A. CONFIRED LAV H ECAM WARNING. NO CLASS 3 FAULTS. INSPECTED LAV H SMOKE DETECTOR NO DEFECTS NOTED AT THIS TIME. RAN PACKS, NO OBVIOUS ODOR OF FUMES AT THIS TIME. OK FSDR CALA2025050604492Power Supply · faultedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - R/H AFT OVERWING ILLUM LIGHT INOP. RELAMPED R/H AFT OVERWING EXIT LIGHT REF AMM 33-51-04-960-801. NO HELP. REPLACED POWER SUPPLY M1671 REF AMM 33-51-06-960-806. OPS CHECK GOOD.SDR CALA2025050604489Cover · detachedECAM LEFT AFT OVER WING EXIT OPEN NOTED MESSAGE ON DOOR PAGE ECAM DISPLAY. FOUND COVER FOR OVER WING EXIT LYING ON FLOOR IN FRONT OF DOOR. UNABLE TO DETERMINE WHY THIS PANEL FELL OFF OR WAS REMOVED. REPLACED PANEL AND DETERMINED THAT IT IS SECURELY INSTALLED. SDR CALA2025050604488Skin · damaged(SUPPORT TASK) R/H WING TRAILING EDGE, LOWER WINT SKIN HAS 4EA ELONGATED HOLES BETWEEN WS 278.50 AND 3025.50(AT THE WIGGLE PLATE). TRANSCRIBED FROM HAECO GSO NR 9285003 REPARIED PER EC/RA NO. 5720-03526SDR WRXR20250505007Cleat · corrodedCORROSION FOUND ON 3 AREAS AT FR 333 BETWEEN STR 25LH-26LH, 26LH-27 AND 25RH-26RH. REMOVED CORROSION ON 3 AREAS AT FR 333 BETWEEN STR 25LH-26LH, 26LH-27 AND 25RH-26RH IAW CRJ 900 SRM 51-21-06-001-001-A01. CUT AWAY LOWER FLANGES BETWEEN STGR 25L AND 25R, FRAME SDR GTIA2025050538902Unknown · odorFUME EVENT -PERFORMED TSM PROC 05-50-00-810-831 RAN BOTH ENGINES AND PACKS WITH CREWS ASSISTANCE COULD NOT DUPLICATE A/C OK FOR SERVICE MOC#57545SDR 2A6R2025050572702Rib · crackedCRACK DAMAGE WAS DISCOVERED ON THE FORWARD BOTTOM LBL 195 RIB (FRAME 1) PN: B531K1341-205. AN APPROVED REPAIR PROCEDURE WAS COMPLIED WITH PER AIRBUS REPAIR DESIGN APPROVAL SHEET RDAS-BK117-53-2025-1107, ISSUE A DATED 02 APR 2025, WHICH CONTAINS A DETAILED DESCSDR CNMA2025050001Longeron · crackedDURING ACCOMPLISHMENT OF INSPECTION 76AD2012-15-12-G, A CRACK WAS FOUND IN THE LH UNDERWING LONGERON. PER SB 767-57A0126 INSTRUCTIONS, THIS REQUIRES FURTHER INSPECTION OF THE STRUCTURE AND AT MINIMUM REPLACEMENT OF THE UNDERWING LONGERON.SDR 2A6R2025050572701Beam · chafedCHAFE DAMAGE WAS DISCOVERED ON THE LOWER CAP OF THE BEAM (PN: 117-22309-38). A DESCRIPTION OF THE DAMAGE AND APPROVED REPAIR PROCEDURES ARE CONTAINED IN AIR METHODS ENGINEERING AUTHORIZATION # 32-5300-EA-5085, INITIAL REVISION DATED 26 MAR 2025 AND IS SUBSTANSDR WX0A2025050532412Megaphone · damaged(AIRCRAFT NOT GROUNDED) MEGAPHONE JUMPSEAT #1 DAMAGED / REMOVED AND REPLACED FWD MEGAPHONE REF AMM 25-65-51-920-001-A. OPS CHECK GOOD"SDR WX0A2025050532411Cover · broken(AIRCRAFT NOT GROUNDED) L1 MAIN CABIN DOOR EXIT LIGHT COVER BROKE OFF. / REMOVED AND REPLACED EXIT LIGHT COVER AT L1 DOOR PER AMM 33-51-13-000-001-A AND AMM 33-51-13-400-001-A, OPS CHECK GOOD, THIS CLEARS NEF 25-01-A07,SDR UIEA2025050500579Beam · corrodedCORROSION - BEAM, L/H WING OUTBD L/E CAVITY LOWER PNL SUPPORT BEAM INNER FACE, AT OLES 1380 AND OLES 1413.(<P>1. BLENDED OUT THE DAMAGE AREA IAW SRM 51-10-02-0G-0 REV: 123. 2. PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET NO: 0477877. 3. MEASURED REWORK AREA