Service difficulty reports
1,770,281 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026103044735Sidewall Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT, WL 165, LBL 25, BS 727C - 807 WAS CORRODED AT SEVERAL LOCATIONS. R & R THE FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, & DWG 146A7500, REV -. INSPECTION REJECTED FOR MISSING FASTENER NUT AT BS 787, LBL 25 ON FLOOSDR SWAA2026103051794Shield · corrodedAT AFT CARGO BAY, FOUND CORROSION ON THE FWD SHIELD FROM BS 767 - 787, RBL 21, WL 165. INSTALLED A NEW SHIELD, BS 767 - 787, RBL 21, WL 165 IAW SRM 51-40-02 AND DWG 146A0081, REV A.SDR SWAA2026103091597Sidewall Support · corrodedCORROSION FOUND FWD CARGO BAY, LH FLOOR TO SIDEWALL SUPPORT AT STA 500I, WL 165, LBL 24, ONE LOCATION. REMOVED CORROSION ON FWD CARGO BAY LT FLOOR TO SIDEWALL SUPPORT BS 500 I WL 165 LBL 24. FOUND TO BE WITHING LIMITS IAW SRM 53-00-53-1A-2.SDR SWAA2026103051063Sidewall Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT WL 165, RBL 25, BS 727C - 767 WAS CORRODED AT SEVERAL LOCATIONS. R & R THE ACB FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, & DWG 146A7500, REV -.SDR SWAA2026103011177Baffle · crackedCRACK FOUND ON THE BAFFLE ANGLE BS 500G, FWD SIDE, RBL 25, WL 162. REMOVED AND REPLACED CLIP ON BAFFLE ANGLE IAW SRM 51-40-02-0G-0, AND DWG 143A7505, REV B.SDR SWAA2026103069529Support · corrodedCORROSION FOUND IN THE FWD CARGO BAY, AFT BULKHEAD LOWER SUPPORT AT BS 500I, WL 165, LBL 24 & RBL 24. REMOVED AND REPLACED FCB AFT BULKHEAD LOWER SUPPORT IAW SRM 51-40-02, & DWG 143A9481, REV-.SDR SWAA2026103024806Threshold Web · corrodedAFT CARGO DOOR FLOOR WEB BTWN BS 787 - 847, WL 165, RBL 25 HAD SEVERAL SPOTS OF CORROSION. INSTALLED A NEW SUB-THRESHOLD WEB IAW SRM 51-40-02, AND DWG 146A8120, REV A.SDR SWAA2026103004168Sidewall Support · corrodedCORROSION FOUND ON THE FWD CARGO BAY, RT FLOOR TO SIDEWALL SUPPORT MULTIPLE LOCATIONS, BS 500A - 500I, WL 165, RBL 24. REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02, AND DWG 143A7500 REV -.SDR IPXA2026102880317Skin · corrodedAFTER REMOVAL OF ADF ANTENNA FOUND UPPER FUSELAGE SKIN WITH DEEP PITTING CORROSION AND TOOLING MARKS. REMPVED CORROSION AT ADF ANTENNA FOUND UPPER FUSELAGE SKIN IAW SRM 51 10-02-0G-0. REINSTALLED 4 EA NUT PLATES AND TREATED & PRIMED AREAS AS REQUIRED AT FWD USDR SWAA2026102709046Stringer · damagedELONGATED FASTENER HOLES (TWO) ON STRINGER 22R, BS 540. REPAIRED STRINGER 22R BTWN BS 500H - 540 IAW SRM 53-00-03-2R-1. REPAIR 1.SDR K11A2026102700408Access Panel · corrodedLEFT HORIZONTAL STAB TRAILING EDGE HAS EVIDENCE OF CORROSION ON LOWER SURFACE FOR ACCESS PANEL AT ELEV STA 149-176SDR SIMA20261003002Floor Support · corrodedRH FLOOR SUPPORT FITTING IS CORRODED BETWEEN FR84 CROSSBEAM AND RH FLOOR SEAT TRACK. (LEVEL 2 CORROSION) REMOVED AND REPLACED RH FLOOR SUPPORT FITTING BETWEEN FR84 CROSSBEAM AND RH FLOOR SEAT TRACK IAW ERJ 170 SRM 51-40-08.SDR IPXA2026102279597Frame · damagedRIGHT ELEVATOR LOWER CONDUCTIVE FRAME REQUIRE CLEAN AND EVALUATE BY CORROSION EVIDENCE, F C/W LOCATED AND DRILLED NEW CONDUCTIVE FRAME P/N 183N2007Y10 TAG 086984 AND FABRICATED SPLICE PLATE AT R/H ELEVATOR LOWER AREA IAW B757-200PF SRM 51-40-05-OG-0 AND DWG 1SDR IPXA2026102279434Bonding Strap · corrodedR/H HORIZONTAL STAB TIP HAS FITTING TO ATTACH BONDING STRAP WITH EXFOLIATION.SDR K11A2026102000403Rib · corrodedL/H HORIZONTAL STAB TRAILING EDGE RIB AT ELEV STA 146 HAS EVIDENCE OF CORROSION ON LOWER SURFACESDR K11A2026102000402Rib · corrodedL/H HORIZONTAL STAB TRAILING EDGE RIB AT ELEV STA 176 HAS EVIDENCE OF CORROSION IN HOLES ON LOWER SURFACESDR SWAA2026101924506Floorboard · delaminatedFLOORBOARD 231RF DELAMINATED. EVALUATED THE FLOOR PANEL AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.SDR SWAA2026101901957Floorboard · delaminatedFLOORBOARD 241NF DELAMINATED. EVALUATED THE FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-63B.SDR SWAA2026101904496Floorboard · delaminatedFLOORBOARD 232JF DELAMINATED. EVALUATED THE FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.SDR SWAA2026101922401Floorboard · delaminatedFLOORBOARD 241FF DELAMINATED. EVALUATED MAIN CABIN FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-00-42A.SDR SWAA2026101967007Floorboard · delaminatedFLOORBOARD 232KF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101904088Floorboard · delaminatedFLOORBOARD 241EF DELAMINATED. EVALUATED FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-00-42A.SDR SWAA2026101929045Floorboard · delaminatedFLOORBOARD 242HF DELAMINATED. EVALUATED THE DAMAGE OUT OF LIMITS IAW SRM 53-00-50-1A. INSTALLED ON CARD TTG8Q01F8TP2.SDR SWAA2026101955433Floorboard · delaminatedFLOORBOARD 231GF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.SDR SWAA2026101967897Floorboard · delaminatedFLOORBOARD 231PF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101943436Floorboard · delaminatedFLOORBOARD 232RF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-00-42A.SDR SWAA2026101983680Floorboard · delaminatedFLOORBOARD 232FF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.SDR SWAA2026101903603Floorboard · delaminatedFLOORBOARD 231MF DELAMINATED, EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101923298Floorboard · delaminatedFLOORBOARD 242GF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-63B.SDR SWAA2026101980589Floorboard · delaminatedFLOORBOARD 231UF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101900737Floorboard · delaminatedFLOORBOARD 242LF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-63B.SDR SWAA2026101927922Floorboard · delaminatedFLOORBOARD 242FF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-63B.SDR SWAA2026101923120Floorboard · delaminatedFLOORBOARD 231NF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101927345Floorboard · delaminatedFLOORBOARD 231ZF DELAMINATED. EVALUATED FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-00-42A.SDR SWAA2026101939215Floorboard · delaminatedFLOORBOARD 241LF DELAMINATED. EVALUATED FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-63B.SDR SWAA2026101938207Floorboard · delaminatedFLOORBOARD 231KF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101978684Floorboard · delaminatedFLOORBOARD 231SF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101998852Floorboard · delaminatedFLOORBOARD 241DF DELAMINATED. EVALUATED THE FLOORBOARD, FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS R & R IAW SRM 53-00-50-1A-1, & AIPC 53-21-00-42A.SDR SWAA2026101957636Floorboard · delaminatedFLOORBOARD 242BF DELAMINATED. EVALUATED THE FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED & REPLACED IAW SRM 53-00-50-1A-1, & AIPC 53-21-00-42A.SDR SWAA2026101961420Floorboard · delaminatedFLOORBOARD 232LF DELAMINATED. EVALUATED THE FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED & REPLACED IAW SRM 53-00-50-1A-1, & AIPC 53-21-51-58B.SDR SWAA2026101944410Floorboard · delaminatedFLOORBOARD 232SF DELAMINATED. EVALUATED THE DAMAGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-50-1A, A NEW FLOORBOARD INSTALLED ON SWA CARD TTG8Q01F8RY4.SDR SWAA2026101921134Floorboard · delaminatedFLOORBOARD 241CF DELAMINATED. EVALUATED THE CABIN FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-00-42A.SDR SWAA2026101980745Floorboard · delaminatedFLOORBOARD 231DF DELAMINATED. EVALUATED THE FLOORBOARD, AND DAMAGE FOUND OUT OF LIMITS IAW SRM 53-00-50-1A. A NEW FLOORBOARD INSTALLED ON CARD TTG8Q01F8MKA.SDR SWAA2026101979918Floorboard · delaminatedFLOORBOARD 231HF DELAMINATED. EVALUATED THE CABIN FLOORBOARD AND FOUND DAMAGE EXCEEDED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.SDR SWAA2026101940782Floorboard · delaminatedFLOORBOARD 241JF DELAMINATED. EVALUATED THE CABIN FLOORBOARD AND FOUND DAMAGE EXCEEDED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-00-42A.SDR SWAA2026101998686Floorboard · delaminatedFLOORBOARD 242EF DELAMINATED. EVALUATED THE CABIN FLOORBOARD AND FOUND DAMAGE EXCEEDED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-63B.SDR SWAA2026101979975Floorboard · delaminatedFLOORBOARD 241HF DELAMINATED. EVALUATED THE CABIN FLOORBEAM & FOUND THE DAMAGE EXCEEDED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-63B.SDR SWAA2026101920191Floorboard · delaminatedFLOORBOARD 241AF DELAMINATED. EVALUATED THE CABIN FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-00-42A.SDR SWAA2026101919948Floorboard · delaminatedFLOORBOARD 242NF DELAMINATED, EVALUATED THE FLOORBOARD AND FOUND THE DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-63B.SDR SWAA2026101939945Floorboard · delaminatedFLOORBOARD 231EF DELAMINATED. EVALUATED THE FLOORBOARD AND FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS. THE FLOORBOARD WAS REMOVED AND REPLACED IAW SRM 53-00-50-1A-1, AND AIPC 53-21-51-58B.