Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202603304829Door · out of adjustAIRCRAFT WAS NOT GROUNDED: LEFT AFT LAVATORY DOOR IS STUCK AND WILL NOT OPEN. ADJUSTED AFT LEFT LAVATORY DOOR. OPS CHECKS GOOD. PER AMM 52-50-01A.SDR AALA202603304862Door · lack of lubeAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR VERY DIFFICULT TO OPEN FROM OUTSIDE. LUBRICATED FLIGH DECK DOOR LATCH. OPS CHECK GOOD. PER AMM 52-51-00.SDR N6WA2025033005Door Frame · corrodedCORROSION ON DOOR POST FS 280 LT SIDE LBL 12. REMOVED AND REPLACED THE DOOR POST IAW SRM 51-42-06, AND 51-42-10.SDR SWAA2026033083734Floor Panel · crackedAFT CARGO FLOOR PANEL 140BF IS CRACKED THRU AT SEVERAL FLOORBEAMS. REMOVED & REPLACED THE FLOOR PANEL 140BF IAW AMM 25-52-10, AND EA M-25-125-02433.SDR SWAA2026033083733Floor Panel · crackedFWD CARGO BAY FLOOR PANEL 120CF WAS CRACKED AT THE CENTER FLOOR BEAM 9 INCHES. REMOVED AND REPLACED THE FLOOR PANEL 120CF IAW AMM 25-52-10, AND EA M-25-125-02432.SDR SWAA2026033083811Battery Pack · no testAFT GALLEY RIGHT F/A JUMPSEAT LEFT FLASHLIGHT WILL NOT TEST. OK TO CONTINUE PER MEL 25-64-02A SP#1B AUTH# 312132. REMOVED AND REPLACED THE BATTERY PACK IAW SIP. OPS CHECKED GOOD.SDR SWAA2026033083876Battery · inoperativeFLIGHT DECK FLASHLIGHT WILL NOT TEST PROPERLY. REPLACED FLASHLIGHT BATTERY IAW AMM 25-64-00.SDR SWAA2026033084060Slide · unpackedL1 DOOR SLIDE FELL OUT OF ITS CONTAINER WHILE OPENING THE DOOR. THE SLIDE DID NOT DEPLOY. REPACKED FWD L1 SLIDE IAW AMM 25-66-01 OPS CK GOOD.SDR SWAA2026033084058Slide · dislodgedL1 DOOR SLIDE FELL OUT OF ITS CONTAINER WHILE OPENING THE DOOR. C/W PER MT 725-61-06.SDR SWAA2026033083844Slide · dislodgedFWD ENTRY DOOR ESCAPE SLIDE FALLING OUT FROM COVER. REINSTALLED FWD ENTRY DOOR SLIDE IAW MT 725-61-06.SDR SWAA2026033083879Lens · missingEXIT SIGN LENS AT EXIT ROW RIGHT MISSING. INSTALLED A NEW EXIT SIGN LENS IAW AMM 33-51-01.SDR SWAA2026033083736Battery Pack · no testEMERGENCY BATTERY PACK AT FWD ENTRY DOOR LEFT M1675 FAILED A CAPACITY CHECK. R & R CABIN EMERGENCY BATTERY PACK IAW AMM 33-51-06.SDR SWAA2026033083815Lens · missingLT. FWD OVERWING EMERGENCY EXIT LOWER LIGHTED EXIT SIGN MISSING LENS.<[01] INSTALLED LOWER LIGHTED EXIT SIGN LENS ON LT. FWD EMERGENCY EXIT IAW AMM 33-51-01.SDR DALA2026033002080Cap · crackedCRACKED CAP BS 1178, & LONG 17L, AFT ACCESORY COMPARTMENT. REPAIRED IAW PRI 632618-14. (1514424)SDR DXTA2026033007429Light · dimDURING PRE-FLIGHT FOUND EXTERIOR OVER WING EMERGENCY LIGHT TO BE EXTREMELY DIM, BARELY WORKING. ALL OTHER EMERGENCY LIGHTS WORK NORMALLY. REMOVED AND REPLACED OVERWING EMERGENCY LIGHT IAW 680A AMM 33-50-20, REV 7. OPERATIONAL CHECKS GOOD.SDR DXTA2026033007436Flap System · vibrationDURING DESCENT FOR LANDING IN NORMAL CONFIGURATION; FLAPS & GEAR UP, SPEED BRAKES RETRACTED, 175KTS, BOTH PILOTS FELT A VIBRATION AND ASSOCIATION SOUND WHEN FLAPS 1 WAS SELECTED. THE VIBRATION AND SOUND CONTINUED UNTIL FLAP 2 WAS SELECTED. THE VIBRATION AND SSDR DXTA2026033007437Engine · vibrationON CLIMB OUT AIRCRAFT DEVELOPED A VIBRATION IT PROGRESSIVELY GOT WORST. ONCE LEVELED OFF, DISENGAGED AUTOTHROTTLES & CONTROL THRUST. BROUGHT RT ENGINE UP, VIBRATION INCREASED LT SIDE NO VIBRATION. RECEIVED ENG VIBRATION RT ROLLED BY ENG EXCEEDENCE RT ITT SDR DALA2026033002078Bottle · low pressureSHIP 3415 3R DOOR ASSIST LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (8064660)SDR DALA2026033002077Bottle · low pressureSHIP 3420 DOOR 3R ASSIST BOTTLE PRESS LOW. CORRECTIVE ACTION: SERVICE DOOR ASSIST BOTTLE PER A330 AMM 52-15. (8340757)SDR IPXA2026033001233Handle · faultedMAIN ENTRY DOOR EXTERIOR HANDLE DOES NOT RETURN TO FLUSH WHEN OPERATED INTERNALLY OR EXTERNALLY. LUBRICATED MAIN ENTRY DOOR EXTERIOR HANDLE IAW AMM 52-11-13. DOOR HANDLE OPS CHECK GOOD FROM BOTH SIDES.SDR IPXA2026033098418A/C Pack · odorEXHAUST SMELL COMING FROM PACKS RAN APU FOR AN HOUR WITH PACKS IN HOT AND THEN COLD, NO SMELLS NOTED, RAN EACH ENGINE AT IDLE WITH NO SMELLS NOTED, RAN EACH ENGINE AT TAKE-OFF POWER SETTINGS WITH PACKS IN HOT AND COLD TEMP SETTINGS, NO ABNORMAL SMELL WAS NOTEDSDR AALA202603302896Door Latch · stickingAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED THAT THE FLIGHT DECK DOOR HARD TO OPEN IN FLIGHT AND THAT THEY HAD TO PUSH WITH BODY WEIGHT TO GET IT TO OPEN. MAINTENANCE CLEANED AND LUBRICATED THE FLIGHT DOOR LATCHES. A SATISFACTORY OPERATIONAL CHECK WAS ACCOSDR AALA202603309455Door · out of adjustAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS THEY WERE UNABLE TO OPEN CENTER LAVATORY DOOR. MAINTENANCE OPENED MID LAVATORY DOOR AND ADJUSTED PER CMM 25-43-24.SDR AALA202603301792Lever · looseAIRCRAFT WAS NOT GROUNDED: SLIDE ARMING LEVER FOR DOOR 2R IS LOOSE. MAINTENANCE SECURED A LOOSE SCREW ON THE SLIDE ARMING LEVER AS REQUIRED.SDR AALA202603309557Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE: L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER WORK CARD 26L80052001.SDR AALA202603307768Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE: R1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER WORK CARD 26L80052001.SDR YENA2026033000350Priority Valve · leakingFLT# 1621 LHR-BOS (ETOPS). FOUND PTU PRIORITY VALVE LEAKING DURING WEEKLY CHK INSP.; REMOVED AND REPLACED YELLOW SYSTEM HYDRAULIC PRIORITY VALVE IAW AMM TASK 29-13-33-000-001-A. LEAK CHK GOOD. GROUND VERIFICATION CHECK GOOD IAW AMM TASK 29-13-33.SDR YENA2026033000348Contactor · damagedFLT 334 SFO-SFO (ETOPS). AFTER ENGINE START HYDRAULIC SYSTEM B LOW PRESSURE.; REF LG 4392214 FOR REMOVED AND REPAIR OF (2705GJ) CONTACTOR. (REF LG 4392214-1: PER TSM 29-12-00810-805-A STEP 2(B) SOL VALVE LEAKAGE MEAS (2160G) CORRECT IN VALVE, NEXT STEP IS MSDR DALA2026033002061Jam-Nut · looseL AFT ENT DOOR EICAS MSG ILLUMINATED AND EXTINGUISHED NUMEROUS TIMES. FOUND JAM NUT AT L4 SENSOR S10097 LOOSE ADJUSTED SENSOR WITHIN LIMITS PER B757AMM 52-71, PERFORMED DOOR WARNING SYS TEST PER B757 AMM 52-71 STAIFACTORY. (7214352)SDR DALA2026033002060Indicator · out of positionL2 DOOR KNUCKLE HAS LARGE GAP WHEN EXTENDED. CORRECTIVE ACTION: RESECURED HARDWARE AS REQUIRED. (8349310)SDR DALA2026033002058Lamp · inoperativeAFT RIGHT PASSENGER DOOR SLIDE ARM LIGHT INOP. ADJUSTED AND RELAMPED RT AFT SLIDE LIGHT INDICATOR PER B757 AMM 25-60. OPS NORMAL. (1515358)SDR DALA2026033002064Slider · dislodgedR4 DOOR AFT GIRT BAR SLIDER DISLODGED. CORRECTIVE ACTION: REPOSITIONED GIRT BAR SLIDER. C/W GIRT BAR INSPECTION AND CHECK PER B757 AMM 25-66. 4R SLIDE ARM/DISARM OPS NORMAL. (8592852)SDR UIEA2026032700110Handle · out of adjustEMERGENCY WINDOW OUTSIDE HANDLE POPS OUT. ADJUSTED SPRING LOADED BALL LATCH OF WINDOW R2 EXTERIOR EMERGENCY ESCAPE HANDLE IAW AMM 56-11-04. OPS CHK GOOD AT THIS TIME.SDR JJBA20260330024Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. OPS CHECKED MAIN DOOR EMERGENCY LIGHT. OPS CHECK SAT. NO DEFECTS NOTEDSDR ABXA20260327135Fire Detector · intermittentRT ENG FIRE LP1 INTERMITTENT DURING ENTIRE FLIGHT. PERF FIM 26-11 FT 804 FOUND RH ENG LWR AFT LOOP READING ONLY 0.9 MEG OHM TO GROUND. REMOVED AND REPLACED AFT LWR LOOP DETECTOR ASSY PER AMM 26-11-02. OPS CHECK GOOD PER AMM 26-11-02. A/C REMAINS NO ETOPS. A/SDR CALA2026033014909Latch · damagedEVACUATION SLIDE RECORD INSTALLATION - PIN BENT ON SLIDE LATCH AT DOOR 1L. REMOVED AND REPLACED LATCH ON DOOR 1L SLIDE AND REINSTALLED SLIDE PER TASK CARD. IAW TASK 25-66-01-400-802SDR CALA2026033014908Gusset · damagedLEFT FR 69 GUSSET NR 4 HAS (5EA) HOLES WITH AN OUT OF ROUND CONDITION. REMOVED AND REPLACED LT FR68 GUSSET NR 4 IAW SRM 51-72-11-911-001, SRM 51-42-11/001, SRM 51-44 -11/001, SRM 51-75-12-911-006, SRM 53-41-79-02-A, SRM 51-76-11/ 001, & SRM 53-41-12-300-018.SDR CALA2026033014907Plate · damagedLEFT FR 68 GUSSET NR 7 HAS (4EA) HOLES WITH AN OUT OF ROUND CONDITION. REMOVED AND REPACED LT FR 68 GUSSET NR 7 IAW SRM 51-72-11-911-001, SRM 51-42-11/001, SRM 51-44- 11/001, SRM 51-75-12-911-006, SRM 53-41-79-02-A, SRM 51-76-11/0 01, AND 53-41-12-300-018.SDR CALA2026033014906Plate · damagedLEFT FR66 GUSSET NR 4 HOLE 3 FROM TOP HAS AN OUT OF ROUND CONDITION WITH CHAMFER. REMOVED AND REPLACED LT FR66 GUSSET NR 4 IAW SRM 51-72-11-911-001, SRM 51-42-11/001, SRM 51-44 -11/001, SRM 51-75-12-911-006, SRM 53-41-79-02-A, SRM 51-76-11/001, AND SRM 53-41SDR CALA2026033014905Plate · damagedLEFT FR66 GUSSET NR 5 HAS (3EA) HOLES WITH A OUT OF ROUND CONDTI ON WITH CHAMFER. REMOVED AND REPLACED LT FR66 GUSSET NR 5 IAW SRM 51-72-11-911-001, SRM 51-42-11/001, SRM 51-44 -11/001, SRM 51-75-12-911-006, SRM 53-41-79-02-A, SRM 51-76-11/001, AND SRM 53-41-SDR CALA2026033014904Intercostal · cracked(SDR) EA 5311-01827 REV G: RG STA 1640 INTERCOSTAL TEE CLIP AREA AT S-14R, CRACK INDICATION NOTED IN ALL LAYERS AT UPPER I/B HOLE. REF NR 136365. ESFR CREATED. PERFORMED REPAIR IN ACCORDANCE WITH VT MAE 757-5360-13-A4278 FIG URES 1 THROUGH 28 WITH NO DEVIATIONSDR CALA2026033014903Elec Connector · disconnectedDUE TO EMERGENCY DECLARED FOR LOW CABIN PRESSURE PLEASE VERIFY BLEED PRESSURES WITH ENGINES RUNNING. REFERENCE 8341812 LOCKING UNLOCKING UNABLE TO MAINTAIN CABIN RATE OF CHANGE OF AT LEAST -500 FEET/MINUET WITH SINGLE (RIGHT) PACK IN HIGH FLOW MODE. FOUND CONNSDR CALA2026033014902Pump · faultedR HYD QTY EICAS FOLLOW- ED BY R HYD SYS PRESS R HYD QTY READS 0FOUND HYD CASE DRAIN HOSE BLOWN. R & R HYD CASE DRAIN HOSE PER AMM SUB TASK 71-00-02-420-057-C7 WHILE LEAK CHECKING HYD CASE DRAIN HOSE DURING ENG RUN THE EDP NEVER CAME ON. R & R RT SYS RETURN FSDR CALA2026033014901Power Supply · inoperativeEMERGENCY LIGHT AFT OF DOOR 2L AND OUTSIDE OF DOOR 2L INOP REMOVED AND REPLACED THE LH AFT EMERGENCY BATTERY POWER SUPPLY. REF AMM 33-51-06. OPS CHECK GOOD.SDR CALA2026033014900Hydraulic Line · brokenIN FLIGHT ECAMG SYS LO PRESSUREG RSVR LO LVLG ENG1 PUMP LO PR LOCKING LOG CAPT STATED THEY FOLOWED PROCEDURES AFTER ECAM WARNING. PUMP RAN APROX 2MIN AFTER ECAM WARNING FOR G HYD LOW PRESS AS THEY FOLLOWED CHECKLIST. HYD FLUID COMING FROM ENG 1 PYLON. ZONE CSDR CALA2026033014889Mount · brokenEMERGENCY LIGHT MOUNT ON 10C BROKE REMOVED AND REPLACED THE EMERGENCY LIGHT MOUNT ON 10C. OPS CHECK GOOD IN REFERENCE TO AMM 33-51-00SDR CALA2026033014888Lamp · inoperativeEMERGENCY LIGHT ANNUNCIATOR (NOT ARMED) INOP REMOVED AND RELAMPED EMERGENCY ANNUNCIATOR LIGHT IN REF AMM 33-18-00-860-012. OPS CHECK GOODSDR CALA2026033014886Unknown · odorSTRONG CHEMICAL ODOR IN AFT GALLEY. OPENED REAR DOORS TO VENTILATE AREA BELIEVE IT WAS CLEANING SOLUTION FROM AC CLEANERS ON BATHROOM FLOORS AREA ODOR DISAPATEDSDR AALA202603309311Beam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FORWARD GALLEY SERVICE DOOR (R1 DOOR) HANDLE LOWER BEAM. REPLACED BEAM PER SRM 20-10-02-01 PROCEDURE 1 AND CMM 52-41-05.SDR QMLA2026032720024Warning Message · illuminatedTRANSMISSION CHIP CAUTION ILLUMINATED MULTIPLE TIMES WHILE IN CRUISE FLIGHT. CAUTION REMAINED ON FOR LAST 3 MINUTES OF FLIGHT.