duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '641364ac46199463bc2e7317d1b75dfb9e091bf7724d20c71f6f5a3b24b1823e' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '641364ac46199463bc2e7317d1b75dfb9e091bf7724d20c71f6f5a3b24b1823e' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
S.B. A300/A310 001-25-19
HIGHLIGHTS To: Holders of A300/A310 Evacuation Slide Systems Service Bulletin A300/A310 001-25-19 Title: Equipment/Furnishings-Emergency Equipment A300/A310 Evacuation Slide Systems Fusible Plug Recall Effectivity: Evacuation Slide System P/Ns D31020-101 and D31021-105 Reservoir and Valve Assembly D17925-105 and D17925-111 Inflation Valve 61202-103, serial numbers listed herein.
To re-call Fusible Plugs LOT P-21 and P-22 installed in inflation valves and inflation systems in service. Fusible Plugs are safety devices which safely vent the pressure from charged inflation systems in the event the inflation systems are subjected to excessive temperatures. Two incidents have been reported from the field where fusible plugs manufactured from the suspect lots have activated below their rated temperature of 174 degrees Fahrenheit. Testing conducted on fusible plug from suspect lots indicate that the plugs activate (vent gas) between the temperature range of 130 to 150 degrees Fahrenheit. Activation of the fusible plugs will vent all gas from the inflation system reservoir rendering the slide unusable.
Comments regarding this Service Bulletin, including those of an editorial nature, should be e-mailed to: technicalpublications@zodiacaerospace.com
No text on this page: it may be a figure. Open the PDF to see it.
S.B. A300/A310 001-25-19 Page 1 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN
EQUIPMENT FURNISHINGS -EMERGENCY EQUIPMENT A300/A310 EVACUATION SLIDE SYSTEMS
FUSIBLE PLUG RECALL
1. Planning Information A. Effectivity A300/A310 Mid Door Evacuation Slide System D31020-101 S/N 0135, 0136, 0137, Reservoir and Valve Assembly D17925-105 Inflation Valve 61202-103 S/N 408-R08-007985, 408-R08-009346, 408-R08-009347 ------------------------------------------------- A300 Emergency Exit Evacuation Slide System D31021-105 S/N 0638 Reservoir and Valve Assembly D17925-111 Inflation Valve 61202-103 S/N 408-R08-007394 Inflation valves, 61201-103, shipped as spares: S/N R08-007395, R08- 007984, R0-007986, R08-009343, R08-009344, R08-009345, R08-009348, R09-500176, R09-500177, R09-500179, R09-503508, R09-503510, and R09-503512.
NOTE: Fusible Plugs, P/N B13984-3, Lot PA-21 or PA-22, shipped from Air Cruisers Company approximate dates of Oct 1, 2008 through Oct 1, 2009.
Fusible plugs shipped as spares could be potentially installed on systems Emergency Exit D31021-101, -103, -107and FWD and Aft Slides D31023-
101. Also potentially installed on Reservoir and Valve assemblies D17925- 105, -107, -109 and on inflation valves 61202-103.
S.B. A300/A310 001-25-19 Page 2 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN B. Reason To recall Fusible Plugs LOT P-21 and P-22 installed in inflation valves and inflation systems in service. Fusible Plugs are safety devices which safely vent the pressure from charged inflation systems in the event the inflation systems are subjected to excessive temperatures. Two incidents have been reported from the field where fusible plugs manufactured from the suspect lots have activated below their rated temperature of 174 degrees Fahrenheit. Testing conducted on fusible plug from suspect lots indicate that the plugs activate (vent gas) between the temperature range of 130 to 150 degrees Fahrenheit. Activation of the fusible plugs will vent all gas from the inflation system reservoir rendering the slide unusable.
C. Compliance It is recommended that this modification be accomplished at the next access to the equipment.
D. Description NOTE: Only those organizations authorized by the FAA or other airworthiness authorities are permitted to perform this modification.
Operators are to check all fusible plugs, B13984-3. Any fusible plug stamped with lot number PA-21 or PA-22 are to be scrapped. Check evacuation system, reservoir and valve assemblies and valves in spares for fusible plugs with the above stated lot numbers. Plugs with suspect lot numbers shall be replaced with new plugs following instructions detailed in the Assembly section of Component Maintenance Manual (CMM) 25-65-02 and/or 25-65-03. Re-identify with marking called out in accomplishment instructions.
E. Approval Certification, TSO-C69 This service bulletin contains modification information which has been submitted to the FAA under the TSO-C69 authorization for the affected articles.
The modification procedures described in this VSB are reviewed and technically accepted by Airbus Design Office to apply to the Airbus fleet affected.
S.B. A300/A310 001-25-19 Page 3 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN F . Labor Hours It will take approximately 0.25 hour per system to accomplish the instructions outlined in this service bulletin.
G. Material - Cost and Availability
(1). EDR (Engineering Data Release) Kit referenced in Paragraph 3, is available at free of charge, 60 days upon receipt of a no charge purchase order which lists the part number and serial number of the system and/or valve. The free of charge condition, and availability, will be in effect for three years after original issue date of the service bulletin, thereafter price and availability upon request.
(2). EDR Kit is available from your local authorized Zodiac Services distributor. Please contact Zodiac Service Europe, Cage Code FAUX0; Zodiac Aerospace UK, Cage Code U03Z8; Zodiac Services Americas, Cage Code 567V9; In-Services Middle East, Cage Code SFB76 or Zodiac Services Asia, Cage Code QC054.
H. Tooling - None.
I. Weight and Balance - None.
J. Electrical Load Data - Not affected.
K. References Air Cruisers Company Service Information Letter (SIL) 25-246.
L. Other Publication Affected Air Cruisers Component Maintenance Manual (CMM) 25-65-03 and/or 25- 65-02 will have to be updated to reflect this service bulletin.
M. Family Tree Charts of Modification Relationships- None.
2. Accomplishment Instructions WARNING: REPLACEMENT OF THE FUSIBLE PLUG SHALL NOT BE
PERFORMED WITH THE RESERVOIR UNDER PRESSURE (CHARGED).
A. Inspect all inflation valves and reservoir and valve assemblies in service.
(1). Inspect all valves, 61202-103, for fusible plugs lot number PA-21 or PA-22.
S.B. A300/A310 001-25-19 Page 4 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN
(2). Inspect all reservoir and valve inflation assemblies for fusible plugs lot number PA-21 or PA-22.
(3). If fusible plug, B13984-3, has a lot number PA-21 or PA-22 remove, discard, and replace with new fusible plug and O-Ring from EDR Kit, reference Paragraph 3. Install and torque per instructions outlined in Assembly section of CMM 25-65-02 and/or 25-65-03.
B. Inspect evacuation system as follows:
(1). Gain access to the reservoir and valve assembly and inspect fusible plug for lot number.
(2). If fusible plug, B13984-3, has a lot number of PA-21 or PA-22 remove, discard, and replace with new fusible plug and O-Ring from EDR Kit, reference Paragraph 3. Install and torque per instructions outlined in Assembly section of CMM 25-65-02 and/or 25-65-03.
(3). Repack evacuation system per applicable folding procedure in Assembly section of CMM 25-60-40 and/or 25-60-42.
(4). Mark “Inspected/Replaced per S.B. A300/A310 001-25-19” in minimum 1/4 inch high characters adjacent to the part identification on the reservoir and valve assembly and adjacent nomenclature placard on the girt/and or lacing cover with indelible contrasting ink.
(5). Return to service.
S.B. A300/A310 001-25-19 Page 5 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN
3. Material Information A. The below EDR (Engineering Data Release) Kit is needed to modify one inflation valve.
* see paragraph 1.G.
New P/N QTY .
Unit List Price Key Word Old P/N Disposition EDR 90-1495-101 1* K i t - Consisting of:
B14056-906 1 - O-Ring B14056-906 Install per applicable CMM B13984-3 1 - Fusible Plug B13984-3 Install per applicable CMM
S.B. A300/A310 001-25-19 Page 6 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN
LOCATION OF RESERVOIR AND VALVE ASSEMBLY FIGURE 1
UNDERSIDE OF SLIDE
RESERVOIR AND VALVE ASSEMBLY
S.B. A300/A310 001-25-19 Page 7 of 8 ISSUE DATE: 27 Aug 2010
SERVICE BULLETIN
TYPICAL LOCATION OF FUSIBLE PLUG ON VALVE FIGURE 2
FUSIBLE PLUG
INFLATION VALVE
AND O-RING
S.B. A300/A310 001-25-19 Page 8 of 8 ISSUE DATE: 27 Aug 2010