Service bulletin · Airbus Helicopters

Revision 5U.S. DOT/FAA - Eurocopter ASB EC135-63A-012 Rev 5 · 31 pages · 1.1 MB

© Airbus Helicopters. Filed by the FAA in regulations.gov docket FAA-2013-0554; AD 2014-05-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2013-0554 (document 0004) · AD 2014-05-01

Manufacturer
Airbus Helicopters
Type
Alert Service Bulletin
Number
EC135-63A-012
Latest revision known
EC135-63A-012, Revision 5, dated September 6, 2011

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

ADs that cite it · 1

Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.

Also cited in 1 proposed AD and 9 difficulty reports.

Text · 31OCR

This text is OCR from a scan. OCR can misread letters and numbers. © Airbus Helicopters. Filed by the FAA in regulations.gov docket FAA-2013-0554; AD 2014-05-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '656e6173c62cd29482f1f675f23f86c781b533d1d1902460b7609510de8b6290'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Page 1OCROpen in PDF

EUROCOPTER EC135

ALERT SERVICE BULLETIN CHANGE INSTRUCTION NO. 5 FOR EC135-63A-012 Date: First issue: 2007-08-08 Revision 01: 2007-12-14 Revision 02: 2008-03-31 Revision 03: 2008-06-16 Revision 04: 2009-04-27 Revision 05: 2011-09-06 Please replace Revision 04 of Alert Service Bulletin EC135-63A-012 with Revision 05.

With Revision 05 no further measures are introduced. The formerly required oil analysis feedback to ECD will no longer be necessary. The oil analysis form sheets have been changed accordingly.

It is no longer required that the laboratory is approved by ECD, but we recommend to choose a laboratory which is approved by ECD. The email address "maintransmission@eurocopter.com" will be deleted.

In order to provide a better overview a table has been introduced on page 2 and the entire Alert Service Bulletin has been divided into four parts:

Part 1: Taking of the Oil Sample Part 2: Evaluation of the oil analysis Part 3: Measures after chip detector indication Part 4: Inspection of the toothing on the drive stages This division shall make the assignment of the individual work steps clearer, e.g. all Sections designated with "Part 1" in the Alert Service Bulletin are associated with taking the oil sample.

Starting with the "Accomplishment", the "Accomplishment Instructions", the associated Figures up to the "Confirmation" of the accomplished work steps.

2011-09-06 PAGE 1 of 1

No text on this page: it may be a figure. Open the PDF to see it.

Page 3OCROpen in PDF

EUROCOPTER AN EADS COMPANY EC135

ALERT SERVICE BULLETIN Main Rotor Drive - Main Transmission - Introduction of an oil analysis and adaption of measures after indication of chip detector

1. Planning Information A. Effectivity

(1) Helicopters affected:

(2) Components affected:

(3) Spare parts affected:

EC135/EC635, all models.

Main transmission P/N 4649 010 003, 4649 010 005, 4649 010 006, 4649 010 006X, 4649 010 008, 4649 010 008X, 4649 001 007, 4649 010 010 and 4649 010 013.

Not applicable.

B. Concurrent Requirements Not applicable.

C. Reason Following several chip indications, several main transmissions were returned to the manufacturer for repair. Within the framework of the inspection of these main transmissions, a partial tooth rupture was detected after removal a drive pinion. This tooth rupture was a follow-up damage caused by excessive wear.

In order to detect wear in time, with this Alert Service Bulletin an oil analysis is introduced for monitoring the condition and the inspection measures following a chip indication are adapted.

D. Description Perform scheduled oil analyses on the main transmission and accomplish given procedures.

Accomplish the given measures following a chip detector indication.

This document is available on the internet: www.eurocopter.com/techpub 2007-08-08 EC135-63A-012 REVISION 05, 2011-09-06 PAGE 1 of 29

Page 4OCROpen in PDF

• EUROCOPTER EC135

ALERT SERVICE BULLETIN E. Compliance NOTE The following table lists an overview of the specified measures. Accomplishment of the measures (Part 1 to Part 4) and the determined stage / water content must be confirmed by an entry in the log card. Please find a detailed list of the measures subsequent to this Table.

Part 1 Take oil sample:

- every 100 th (+10 th tolerance), at least once a year

- if required by the analysis i.a.w. Part 3 Note: 25 fh after Part 1 the oil analysis must be accomplished i.a.w. Part 2.

Part 2 Analyze and evaluate oil sample:

- within 25 fh after the oil sample has been taken Viscosity too low (within 25 th Remove oil filter element and inspect it (Part 3) after oil analysis) Inspect toothing (Part 4) Accomplish oil change Water content Perform oil change within 10 fh after the oil analysis has been accomplished between 0.1 % and 0.5 % Water content Accomplish oil change before the next flight more than 0.5 % After the third entry "water content more than 0.5 %" has been made, inspect toothing within 50 fh after the oil analysis has been accomplished (Part 4).

Stage I No further measures required Stage II (within 25 fh after the oil Remove oil filter element and inspect it (Part 3) analysis) Inspect toothing (Part 4) Accomplish oil change Stage III (within 10 fh after the oil Remove oil filter element and inspect it (Part 3) analysis) Inspect toothing (Part 4) Accomplish oil change Part 3 Analyze and evaluate chips:

- when chip detector is indicated Stage A Remove oil filter element and analyze chips (Stage A - D).

After stage A has been reported twice: Inspect toothing within 10 fh (Part 4).

Stage B Remove oil filter element and analyze chips (Stage A - D).

Inspect toothing within 10 fh (Part 4).

Perform ground run and then re-inspect the chip detector.

Stage C Remove oil filter element and analyze chips (Stage A - D).

Inspect toothing before the next flight (Part 4).

Take an oil sample and analyze it (Part 1 and 2).

After stage C has been reported twice: Accomplish the measures of stage D within 50 fh.

Stage D Take an oil sample (Part 1) Collect chips for analysis.

Send main transmission with chips and oil sample / oil analysis to the manufacturer for repair before the next flight.

Part 4 Inspect toothing on the drive stages:

- if required by the analysis i.a.w. Part 2 or Part 3 Tooth image i.a.w. Figure 11, 12, admissible wear, no replacement required green area Tooth image i.a.w. Figure 11, 12, not admissible wear, remove main transmission and send it to the manufacturer.

red area EC135-63A-012 2007-08-08 PAGE 2 of 29 REVISION 05, 2011-09-06

Page 5OCROpen in PDF

EUROCOPTER AN EADS COMPANY EC135

ALERT SERVICE BULLETIN Part 1: Taking of the Oil Sample:

EFFECTIVITY EC135/EC635 up to and including S/N 0504.

1. If a previous revision of this Alert Service Bulletin has not been carried out the first oil sample must be taken i.a.w. Section 3, Part 1 within 100 th or one year from the last oil change or at the next oil change (see Note).

EFFECTIVITY All EC135/EC635.

1. The first oil sample must be taken within 100 fh after the last oil change (see Note) has been done.

2. After the first oil sample has been taken other oil samples must be taken i.a.w. Section 3, Part 1 in regular intervals within 100 th (see Note), but at least once a year. On accomplishment of the oil change the oil analysis is set back to O fh and then starts over NOTE For the taking of the oil sample a tolerance of 10% (90 th to 110 fh) applies.

If the oil sample is carried out at same time as oil change the oil sample is to be carried out prior to the oil change.

Part 2: Evaluate the oil analysis and start measures:

EFFECTIVITY All EC135/EC635.

The oil sample must be analyzed i.a.w. Section 3, Part 2 within 25 th after the oil sample has been taken. Prior to evaluation of the oil analysis results the helicopter may be operated without restrictions.

Part 3: Measures after chip detector indication:

EFFECTIVITY All EC135/EC635.

If the chip detector indication illuminates the chip detector must be checked i.a.w.

Section 3, Part 3 of this Alert Service Bulletin and an entry in the log card of the main transmission must be made. This Alert Service Bulletin takes precendence over the AMM task until such time as the Alert Service Bulletin is incorporated into the AMM.

EFFECTIVITY All EC135/EC635 with a main transmission TT, TSO, TSR that has more than 300 fh.

1. If an issue of this Alert Service Bulletin has already been accomplished before Revision 04 was issued, the log card of the main transmission must be checked immediately for entries regarding to chip indications. If, within the last 300 fh, stage A has been entered twice or stage B has been entered once in the log card, the toothing must be inspected

i.a.w. Section 3, Part 4 within 10 fh.

2007-08-08 EC135-63A-012 REVISION 05, 2011-09-06 PAGE 3 of 29

Page 6OCROpen in PDF

→ EUROCOPTER EC135

ALERT SERVICE BULLETIN

2. In future, the toothing must be inspected i.a.w. Section 3, Part 4 within 10 fh after the second chip detector indication i.a.w stage A or after the first chip detector indication

i.a.w stage B. Make an entry in the log card of the main transmission.

3. In future, the measures i.a.w. stage D must be accomplished within 50 th after the second chip indication i.a.w. stage C has occurred.

Part 4: Inspect toothing on the drive stages:

EFFECTIVITY All EC135/EC635.

The toothing must be inspected i.a.w. Section 3, Part 4 whenever the measures after the chip detection or the measures after the oil analysis require the inspection.

2. If pitting or spalling i.a.w Figure 11 or 12 is detected, during accomplishment of the inspection i.a.w Section 3, Part 4, the transmission must be replaced before the next flight.

F. Approval The technical content of this document is approved under the authority of DOA No. EASA.21J.034.

G. Manpower Not applicable.

H. Weight and Balance Not applicable.

Electrical Load Data Not applicable.

J. Software Accomplishment Summary Not applicable.

K. References

- AMM EC135

- AMM EC135/635 L. Other publications affected The changes to AMM/MSM EC135 and AMM/MSM EC135/635 which are required as a result of this Alert Service Bulletin will be incorporated with one of the next revisions.

EC135-63A-012 2007-08-08 PAGE 4 of 29 REVISION 05, 2011-09-06

Page 7OCROpen in PDF

EUROCOPTER AN EADS COMPANY EC135

ALERT SERVICE BULLETIN M. Interchangeability of Parts Not applicable.

2. Material Information A. Material - Price and Availability Information on cost and availability of required retrofit kit SB-135-63A-012-2C will be provided by ECD, Dept. Spares Order Administration on request.

B. Support Information Not applicable.

C. Material Necessary for Each Helicopter Retrofit kit SB-135-63A-012-2C. The material kit is needed for the inspection i.a.w. Section 3, Part 4.

No. New P/N Keyword Old P/N Qty Remark 0634313288 O-ring 0634313288 2 0634316171 O-ring 0634316171 2 Remark:

A = New, included in kit.

D. Material Necessary for Each Spare Not applicable.

E. Reidentified Parts Not applicable.

F. Special Tooling

- Testing probe with a ball diameter at the tip of 0.3 - 0.5 mm (dental tool, WHO parodontometer, e.g. parodontometer P-WHO 11,5, )

- Guide bolt (made from a screw M6 with a shank length of 80 mm, see Figure 15) 2007-08-08 EC135-63A-012 REVISION 05, 2011-09-06 PAGE 5 of 29

Page 8OCROpen in PDF

→ EUROCOPTER EC135

ALERT SERVICE BULLETIN

3. Accomplishment instructions Part 1: Taking of the Oil Sample:

A. Preconditions:

- Do not refill new oil immediately before the oil analysis.

- The oil samples may not be taken directly from the transmission bottom or from the filter housing.

- Container and sample syringe must be free of any deposits.

- Protective caps of the sample syringe and the container may only be removed immediately before the sample is taken and must be re-installed immediately after the sample has been taken.

- The oil must have reached its normal operating temperature (approx. 50 to 70 degrees centigrade) and well mixed. Therefore, the oil sample should be taken within 10 minutes after engine shutdown.

B. Take oil sample:

(1) Open oil filler neck (Figure 1) and remove oil filter element.

(2) Take oil sample by means of a syringe (Figure 1) and fill approx. 50 ml into the provided bottle.

(3) It is important that the complete data is given and sent together with the oil sample for analysis:

- S/N, TT (Total Time) and TSO (Time Since Overhaul) of the main transmission

- Operating time of the oil in th

- Oil type

- S/N and TT of the helicopter

- Operator

- Date C. If necessary, refill oil i.a.w. AMM, 63-21-00, 3-2.

D. Have oil analysis accomplished in a laboratory. It is recommended to choose a laboratory that is approved by EC (see http:/www.eurocoptersea.com.sg/dlctr/laboratories.html).

Determine proportions of iron (Fe) contained in the oil. Determine viscosity at 100°C i.a.w.

DIN 51562 and water content in weight-%.

EC135-63A-012 2007-08-08 PAGE 6 of 29 REVISION 05, 2011-09-06

Page 9OCROpen in PDF

EUROCOPTER AN EADS COMPANY EC135

ALERT SERVICE BULLETIN Part 2: Evaluate oil analysis:

A. Document oil analysis:

Using Figure 2 (oil i.a.w. MIL-PRF-23699) or Figure 3 (oil i.a.w. ZFN-L-3001) and enter values as shown in example (Figure 4). Carry out procedures according to determined stage ( to III) and to viscosity and water content values:

NOTE If SB EC135-63-011 (retrofit to a more efficient lubricating oil) has been accomplished recently, the increased cleansing property of the new oil may possibly falsify the results of the oil analysis. This increased cleansing property of the oil may separate deposits from the housing and keep them floating. This can cause increased analysis values and also lead to more deposits on the chip detector. Contact ECD customer support if any clarification is required for oil sample results.

B. Viscosity:

(1) The standard value for lubricating oil i.a.w. MIL-PRF-23699 is 4.9 to 5.4 mms. If the value is below 4.9 mms, accomplish measures i.a.w. stage I.

(2) The standard value for lubricating oil i.a.w. ZFN-L-3001 is at least 7 mms. If the measured value is less than the given value, accomplish measures i.a.w. stage II.

C. Water content:

The limiting value for the water content is 0.1%. If this value is exceeded:

(1) If the water content is between 0.1 and 0.5%, accomplish an oil change within the next 10 fh.

(2) If the water content is greater than 0.5%, accomplish an oil change before the next flight.

(3) Enter process in the log card of the main transmission.

- After the third entry in the log card has been made, the measures i.a.w. stage II must be accomplished within 50 fh.

D. Stage I:

No further measures required.

E. Stage II:

The following measures are required within 25 fh:

(1) Remove oil filter element i.a.w. AMM, 63-21-00, 4-5 and inspect i.a.w. Section 3, Part 3 of this Alert Service Bulletin. Clean oil filter element i.a.w. AMM, 63-21-00, 7-2 and install.

2007-08-08 EC135-63A-012 REVISION 05, 2011-09-06 PAGE 7 of 29

Page 10OCROpen in PDF

• EUROCOPTER EC135

ALERT SERVICE BULLETIN

(2) Have toothing inspected i.a.w. Section 3, Part 4. During this inspection the transmission remains on the helicopter. If there is a chip detector indication within these 25 fh inspect the chip detector i.a.w. Section 3, Part 3.

(3) Accomplish oil change.

F. Stage III:

The following measures are required within 10 th:

(1) Remove oil filter element i.a.w. AMM, 63-21-00, 4-5 and inspect i.a.w. Section 3, Part 3 of this Alert Service Bulletin. Clean oil filter element i.a.w. AMM, 63-21-00, 7-2 and install.

(2) Have toothing inspected i.a.w. Section 3, Part 4.

(3) Accomplish oil change.

Part 3: Measures after chip detector indication:

NOTE The findings and measures described for the chip detector (1, Figure 6) are also effective for particles that are found in the oil filter element and the filter of the chip detector housing (2).

A. Remove chip detector i.a.w. AMM, 63-40-00, 4-1 and analyze deposits on the chip detector

i.a.w. the following table and start measures:

Deposits i.a.w. Figure 5, stage A:

Findings Possible Measures causes Slight abrasion Normal (a) Clean chip detector and install.

wear

(b) Remove oil filter element i.a.w. AMM, 63-21-00, 4-5 and check for deposits and chips. Analyze deposits. If no chips are present, clean oil filter element i.a.w. AMM, 63-21-00, 7-2 and install.

(c) Enter the chip indication in the log card of the main transmission.

(d) On main transmissions with TT, TSO, TSR more than 300 th: Inspect toothing i.a.w.

Section 3, Part 4 within 10 fh, after the second chip indication has been indicated.

EC135-63A-012 2007-08-08 PAGE 8 of 29 REVISION 05, 2011-09-06

Page 11OCROpen in PDF

EUROCOPTER AN EADS COMPANY EC135

ALERT SERVICE BULLETIN Deposits i.a.w. Figure 5, stage B:

Findings Possible Measures causes Increased slight Normal (a) Accomplish measures (a) to (c) i.a.w.

abrasion, no chips wear or first stage A.

signs of a damaged (b) On main transmissions with TT, TSO, TSR more than 300 fh: Inspect toothing i.a.w.

transmission Section 3, Part 4 within 10 fh.

(c) Accomplish ground run (duration 15 min, at power setting IDLE) and then reinspect chip detector.

Deposits i.a.w. Figure 5, stage C:

Findings Possible Measures causes Some chips, Damaged (a) Accomplish measures (a) to (c) i.a.w.

triangular to gear wheel stage A.

trapezoidal. One side is smooth (b) Inspect toothing i.a.w. Section 3, Part 4 before with still the next flight.

recognizable (c) Additional take an oil sample and accomplish working structure oil analysis (Section 3, Part 1 and 2).

or scoring, the other side with (d) After the second chip indication i.a.w. stage C tracture. has occurred the measures i.a.w. stage D must be accomplished no later than within 50 th.

Deposits i.a.w. Figure 5, stage D:

Findings Possible Measures causes Several very thin Damage to (a) Take oil sample.

chips which shine the bearing (b) Collect chips for analysis.

bright on one side in increased (c) Send main transmission with chips and oil sample abrasion. / oil analysis to the manufacturer for repair before the next flight.

2007-08-08 EC135-63A-012 REVISION 05, 2011-09-06 PAGE 9 of 29

Page 12OCROpen in PDF

• EUROCOPTER EC135

ALERT SERVICE BULLETIN Part 4: Inspect toothing on the drive stages:

A. Remove drive shaft i.a.w. AMM, 63-11-00, 4-1.

B. Remove drive stage:

CAUTION DO NOT INTERCHANGE COMPONENTS OF THE LH AND RH DRIVE STAGE. THEREFORE, ONLY ONE DRIVE SHAFT AT A TIME MAY BE REMOVED AND INSPECTED. BEFORE THE

SECOND DRIVE STAGE IS INSPECTED, THE FIRST DRIVE STAGE MUST BE REINSTALLED.

(1) If necessary, remove dirt and deposits from the entire circumference of the drive stage.

To do so, use a lint-free cloth or a piece of paper. Do not use cleaning solvents.

(2) Before removal, mark the position of shim (3, Figure 7), bearing (2) and cover (1) against each other (1, Figure 8). Mark bearing housing with either LH or RH (2).

(3) Remove oil nozzle (3, Figure 8).

(4) Using hot air blower (4, Figure 8), heat housing to a maximum of 60 degrees centigrade.

NOTE Wear lint-free gloves for the removal of the drive stage.

(5) Remove six of the seven hexagon head screws (1, Figure 9). In order to secure the drive stage, the uppermost hexagon head screw (2) remains tightened.

(6) Hold drive stage with one hand and remove the remaining hexagon head screw 2, Figure 9).

CAUTION WHEN REMOVING THE DRIVE STAGE, IT MUST BE ENSURED THAT

THE DRIVE STAGE DOES NOT SLIP OUT, THAT THE INDIVIDUAL

PARTS - ESPECIALLY SHIM, BEARING AND COVER - ARE REMOVED TOGETHER AND THAT THE SHAFT SEAL IN THE COVER (1, FIGURE

7) IS NOT TILTED OR TWISTED.

(7) Pull out drive stage (3, Figure 9).

(8) Protect opening of housing from contamination.

(9) Put drive stage onto flange of free wheel shaft (5, Figure 7).

(10) Secure drive stage components with two hexagon head screws (6), washers (7) and nuts (8).

(11) In order to remove the residual oil (approx. 0.1 liters), turn drive stage by 180 degrees and drain oil in a container. To do so, hold drive stage in this position.

EC135-63A-012 2007-08-08 PAGE 10 of 29 REVISION 05, 2011-09-06