Other document · Airbus

Revision 1AOT_A25N027-23_Rev1 · 9 pages · 604 KB

© Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-2025, the docket of AD 2024-23-09. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2024-2025 (document 0006) · AD 2024-23-09

Manufacturer
Airbus
Type
All Operators Transmission
Number
A25N027-23
Latest revision known
A25N027-23, Revision 1, dated February 26, 2024

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

Text · 9

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document. © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-2025, the docket of AD 2024-23-09. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'efb7b674a91ef4d3b8b5fda6cee27c25aec40c426100ab2b72f0c1b893e16347'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 1 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT SUBJECT: ATA 25 – Door 3 Escape slide and Offwing slide inflation reservoirs orifice fitting inspection AIRCRAFT TYPE: A321-200NX OUR REF.: A25N027-23 Rev 01 dated 26-Feb-2024 OUR PREVIOUS REF.: A25N027-23 Rev 00 dated 16-Jan-2024 EFFECTIVITY DATE: 19-Jan-2024

0. REASON FOR REVISION The reasons for the revision 01 of this AOT A25N027-23 are :

- to inform about EASA AD 2024-0048 release,

- to clarify the aircraft type applicability,

- to enable the removal of the reservoir unit for rectification purpose off-wing,

- to inform about the extension of the affected SN list within the revision 01 of Safran VSB Ref. 2 and Ref. 3, leading to additional work if the AOT instructions have been completed with the previous revision.

The revised paragraphs are indicated between ***BEG. REV*** and ***END REV***.

1. AIRCRAFT AFFECTED ***BEG. REV*** This AOT is applicable on All A321NX aircraft (i.e. NEO / ST8), namely :

A321-251NX, A321-252NX, A321-253NX, A321-271NX, A321-272NX, equipped with Door 3 & Offwing Evacuation Systems inflation reservoirs Part Numbers (PN), listed below:

the Door 3 Evacuation Systems inflation reservoir PN 70197-101 with affected SN listed in Ref.

2.

the Offwing Evacuation Systems inflation reservoirs PNs 70200-101, -102, -103, -104 with affected SN listed in Ref. 3.

For aircraft that have Airbus MOD 161964 and 161796 embodied in production, the inspection as required in the paragraph 5.4. INSPECTION does not need to be accomplished for affected parts installed on door 3 FIN 7693MM and 7694MM.

The above PNs are installed on the following locations:

Location PN FIN A321NX, LH Emergency exit door 3 slide reservoir, Overhead storage compartment (OHSC) 70197-101 7693MM A321NX, RH Emergency exit door 3 slide reservoir, OHSC 70197-101 7694MM A321NX, LH offwing slide reservoir, cargo compartment 70200-101 7683MM

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 2 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT A321NX, RH offwing slide reservoir, cargo compartment 70200-102 7684MM A321NX, LH offwing slide reservoir, OHSC 70200-103 7685MM A321NX, RH offwing slide reservoir, OHSC 70200-104 7686MM ***END REV***

2. REFERENCED DOCUMENTATION

2.1 APPENDIX Not applicable.

2.2 REFERENCES ***BEG. REV*** Ref. 1: EASA AD 2024-0048 - ATA 25 - Equipment/Furnishings - Escape Slide and Offwing Slide Inflation Reservoir Venting Holes - Inspection / Replacement Ref. 2: SAFRAN VSB A321 005-25-45 Rev 01 “Inspection/Replacement of Contaminated Orifice Fitting P/N M3SP-303-004-E” for Door 3 Evacuation Systems manufactured by Air Cruisers Ref. 3: SAFRAN VSB A321 005-25-46 Rev 01 “Inspection/Replacement of Contaminated Orifice Fitting P/N M3SP-303-004-E” for Offwing Evacuation Systems manufactured by Air Cruisers Ref. 4: AMM task 25-62-49-000-001-A - Removal of the Door 3 Escape-Slide Inflation Reservoir Ref. 5: AMM task 25-62-46-000-001-A - Removal of the Inflation Reservoir for the Offwing Escape Slide Ref. 6: AMM task 25-62-00-481-001 - Special Precautions before You Do Work on the Offwing/Emergency-Exit-Door Escape-Slide Systems Ref. 7: AMM task 25-62-00-081-001 - Special Precautions after You Do Work on the Offwing/Emergency-Exit-Door Escape-Slide Systems Ref. 8: AMM task 25-62-49-400-001-A - Installation of the Door 3 Escape-Slide Inflation Reservoir Ref. 9: AMM task 25-62-46-400-001-A - Installation of the Inflation Reservoir for the Offwing Escape Slide Ref. 10: ISI article Ref. 25.62.00054

3. REASON This AOT is issued to advise the A321NX operators about a quality escape detected on A321NX Door 3 & Offwing inflation reservoirs’ venting holes [a torque strip indicator (material “Dykem”) has been applied on the orifice fitting] and to request the rectification of the inflation reservoir regulator valve.

All slide reservoirs installed (affected slide PN and FIN are mentioned in this AOT, paragraph 1.

AIRCRAFT AFFECTED, for affected SN refer to Ref. 2 and Ref. 3) on aircraft are concerned by this AOT.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 3 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT All spare parts (for affected SN refer to Ref. 2 and Ref. 3) shall be inspected in accordance with Ref. 2 and Ref. 3 instructions prior installation on aircraft.

***END REV***

3.1 FACTS The orifice fitting in the pneumatic system, P/N M3SP-303-004-E, is a redundant feature to vent an accumulation of pressure from a potential leak of inflation gas from the outlet of the inflation regulator valve.

A torque strip indicator (material “Dykem”) has been applied on the orifice fitting.

This may lead to an unintended deployment of the evacuation slide in flight.

A number of systems with a clogged orifice fitting are suspected having been shipped from the supplier factory.

3.2 HISTORY/BACKGROUND *** BEG. REV*** The evacuation systems, installed on A321NX Emergency exit Door 3 and Offwing door, is fitted with venting features which ensure redundancy to vent gas leakage accumulation as seen in below Figures 1 and 3:

the packed slide system is incorporating a check valve, the reservoir regulator valve outlet port is fitted with an orifice fitting.

Figure 1: Example of the location of the orifice fitting on the reservoir

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 4 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT ***END REV***

3.3 ROOT CAUSE A torque strip indicator (Material “Dykem”) has been applied on the orifice fitting as described in Figure

2.

This torque strip indicator may clog the venting hole.

Figure 2: Example of the orifice fitting on the reservoir with strip indicator applied

3.4 INVESTIGATION Investigation in supplier’s production has revealed such a clogged orifice fitting.

3.5 CONSEQUENCES As per Figure 3 below, if gas leakage accumulates from the reservoir regulator valve, whilst there is no capability of venting the gas, there is a risk of slide enclosure door panel release and soft cover opening during flight.

Indeed, if the slide pneumatic piping system is unexpectedly pressurized, there is a risk of activation of both the enclosure ball locks and locking lacing cover actuator.

Nevertheless, gas leakage accumulation will not trigger the activation of the reservoir and therefore the inflation of the slide inflatable assy.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 5 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

Figure 3 : Slide Pneumatic System design

4. OBJECTIVES OF THIS AOT This AOT recommends checking whether the Torque strip clogs the orifice fitting.

*** BEG. REV*** In the case the “Dykem” marking is not present as per Figure 1, no rectification action is required.

*** END REV*** In the case the “Dykem” marking is present as per Figure 2, the orifice fitting shall be removed and replaced.

5. MAINTENANCE PROCEDURE NOTE: This AOT is classified mandatory or expected to be classified mandatory by an Airworthiness Directive (AD). If the instructions of this AOT are marked as Required for Compliance (RC), the operator must follow the instructions as indicated. These instructions are introduced by “in accordance with”.

NOTE: The instructions of this AOT include procedures given in other documents or in other sections of the AOT. If the instructions of this AOT are NOT marked as Required for Compliance (RC), the operator can use an alternative procedure accepted by his/her local authority. These instructions are introduced by “refer to”.

NOTE: When this AOT gives the access or close-up instructions with no return to service tests, the operator can adapt these instructions to add flexibility to the maintenance operations. The technical intent of this AOT must comply with the set parameters.

5.1 PLANNING – (RC) *** BEG. REV*** Airbus recommends to perform the inspection of the reservoir of the affected slides in accordance with Ref. 2 and Ref. 3 installed on aircraft within the next 04 months after 19-Jan-2024 (effective date of the AOT initial issue).

5.2 MANPOWER

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 6 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT Referring to Ref. 2 and Ref. 3, inspection of systems, including aircraft preparation and time to gain access, will take approximately 0.25 hour for each affected unit, and the accomplishment of Ref. 2 or Ref. 3 will take approximately 0.25 hour for each affected unit.

NOTE: When launching this inspection, it is recommended to make sure that sufficient time is available before the next flight, to perform the corrective action in case of finding.

5.3 ACCESS Refer to AMM tasks Ref. 4 for Door 3 Escape slide reservoir and Ref. 5 for Offwing slide reservoir.

Put the ACCESS PLATFORM 2M (6 FT) in position below the aft cargo-compartment door.

5.4.INSPECTION – (RC) To perform this AOT, the operators are required to identify the potentially affected inflation reservoirs in accordance with Ref. 2 and Ref. 3:

- using applicable maintenance records, AND/OR

- by visual inspection of the inflation reservoirs installed on aircraft, AND/OR

- using spare stock listing/records.

For the identified reservoirs, the operators are required to inspect the orifice fitting for the presence of "Dykem" marking applied to the top surface (example of “Dykem” application shown in Figure 2).

5.5 FINDINGS – (RC) On the identified reservoir units :

If “Dykem” marking is present on the orifice fitting, apply the rectification instructions provided within paragraph 5.6 INSTRUCTIONS – (RC).

If “Dykem” marking is not present, no rectification is required and the marking identification instructions are to be accomplished in accordance with Ref. 2 or Ref. 3.

5.6 INSTRUCTIONS – (RC) A. Spare parts rectification

(1) For Door 3 Evacuation Systems : Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 2.

Installation torque of new fitting is detailed in Ref. 2. for A321NX Door 3 Evacuation Systems inflation reservoirs PN 70197-101.

(2) For Offwing Evacuation Systems : Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 3.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 7 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT Installation torque of new fitting is detailed in Ref. 3. for A321NX Offwing Evacuation Systems inflation reservoirs PNs 70200-101, -102, -103, -104.

(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in accordance with Ref. 2 or Ref. 3.

B. On-wing rectification of A321NX Door 3 Evacuation Systems inflation reservoirs ***END REV*** WARNING:

MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:

DISCHARGE OF THE INFLATION RESERVOIR DEPLOYMENT OF THE ESCAPE SLIDE WHICH CAN CAUSE INJURY AND/OR DAMAGE.

WARNING:

MAKE SURE THAT YOU TURN THE REGULATOR ASSEMBLY IN A CLOCKWISE DIRECTION OR IN THE DIRECTION OF THE BLACK MARK. WHEN YOU TURN THE REGULATOR ASSEMBLY IN THIS DIRECTION, THE VALVE CLOSES.

IF YOU DO NOT OBEY THIS INSTRUCTION, YOU WILL START AN UNWANTED DEPLOYMENT SEQUENCE.

THIS CAN CAUSE INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.

*** BEG. REV***

(1) Do the special precautions before you work on the escape slide system(s) in accordance with Ref.

6.

CAUTION:

ESCAPE-SLIDE INFLATION RESERVOIR MAY DISCHARGE IF LOCK PIN IS NOT INSTALLED.

- Ensure the lock pin assembly is installed in the regulator valve assembly of the inflation reservoir.

(2) Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 2.

Installation torque of new fitting is detailed in Ref. 2. for A321NX Door 3 Evacuation Systems inflation reservoirs PN 70197-101.

NOTE : The new orifice fitting can be installed on the affected reservoir either on-wing or after removal from the aircraft in accordance with Ref. 4.

The replacement by a serviceable part is also an acceptable means of compliance to the AOT instructions.

(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in accordance with Ref. 2.

(4) Do the special precautions after you worked on the escape slide system(s) in accordance with Ref.

7.

CAUTION:

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 8 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

MAKE SURE THAT THE LOCK PIN IS REMOVED FROM THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. IF IT IS NOT REMOVED, IT CAN PREVENT THE INFLATION OF THE ESCAPE SLIDE/RAFT.

- Ensure the lock pin assembly is removed from the regulator valve assembly of the reservoir and installed in the pocket.

(5) Remove the safety clip(s) and tag(s) if installed, close the circuit breaker(s) if previously opened and do the “5. Close-up” paragraph with reference to Ref. 8.

C. On-wing rectification of A321NX Offwing Evacuation Systems inflation reservoirs ***END REV*** WARNING:

MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:

DISCHARGE OF THE INFLATION RESERVOIR DEPLOYMENT OF THE ESCAPE SLIDE WHICH CAN CAUSE INJURY AND/OR DAMAGE.

WARNING:

MAKE SURE THAT YOU TURN THE REGULATOR ASSEMBLY IN A CLOCKWISE DIRECTION OR IN THE DIRECTION OF THE BLACK MARK. WHEN YOU TURN THE REGULATOR ASSEMBLY IN THIS DIRECTION, THE VALVE CLOSES.

IF YOU DO NOT OBEY THIS INSTRUCTION, YOU WILL START AN UNWANTED DEPLOYMENT SEQUENCE.

THIS CAN CAUSE INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.

***BEG. REV***

(1) Do the special precautions before you work on the escape slide system(s) in accordance with Ref.

6.

CAUTION:

ESCAPE-SLIDE INFLATION RESERVOIR MAY DISCHARGE IF LOCK PIN IS NOT INSTALLED.

- Ensure the lock pin assembly is installed in the regulator valve assembly of the inflation reservoir.

(2) Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 3.

Installation torque of new fitting is detailed in Ref. 3. for A321NX Offwing Evacuation Systems inflation reservoirs PNs 70200-101, -102, -103, -104.

NOTE : The new orifice fitting can be installed on the affected reservoir either on-wing or after removal from the aircraft in accordance with Ref. 5.

The replacement by a serviceable part is also an acceptable means of compliance to the AOT instructions.

(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in accordance with Ref. 3.

(4) Do the special precautions after you worked on the escape slide system(s) in accordance with Ref.

7.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A25N027-23 Rev 01 Page 9 of 9 Date: 26-FEB-2024 C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT CAUTION:

MAKE SURE THAT THE LOCK PIN IS REMOVED FROM THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. IF IT IS NOT REMOVED, IT CAN PREVENT THE INFLATION OF THE ESCAPE SLIDE/RAFT.

- Ensure the lock pin assembly is removed from the regulator valve assembly of the reservoir and installed in the pocket.

(5) Remove the safety clip(s) and tag(s) if installed, close the circuit breaker(s) if previously opened and do the “5. Close-up” paragraph with reference to Ref. 9.

5.7 SPARES AND TOOLING Refer to Ref. 2 and Ref. 3 for necessary materials and tooling.

6. ADDITIONAL INFORMATION ISI article Ref. 10 is available for further information.

6.1 FOLLOW-UP PLAN This AOT has been classified Mandatory by the Ref. 1 released the 16 February 2024.

The Ref. 1 has to be accomplished within 3 months after the effective date : 01 March 2024.

***END REV***

6.2 IMPACTED DOCUMENTATION Not applicable.

7. AOT APPROVAL The technical content of this document is approved under the authority of the DOA ref.EASA.21J.031.

8. REPORTING Address your AOT embodiment status (with reservoir PN, SN and FIN location) to Airbus Customer Services through the generic e-mail address: inspection.results@airbus.com. Refer to the latest reporting policy (Ref in the OIT 999.0018/16).

Give the AOT reference in the mail title, as follows: { AOT A25N027-23} Embodiment status You can address your questions about this AOT to Airbus Customer Services through TechRequest on Airbus World, selecting Engineering Domain Section Engineering Support and ATA 25-62 / Topic AOT A25N027-23 Escape slide and Offwing slide inflation reservoirs orifice inspection.

Best Regards, Wolfgang WOHLERS

HEAD OF ENGINEERING AND MAINTENANCE Jean-Pierre GOMEZ VICE PRESIDENT A320 PROGRAMME

CUSTOMER SERVICES