Other document · Airbus

No revision namedU.S. DOT/FAA - Service Information - 1 · 7 pages · 1.8 MB

© Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0995; AD 2012-25-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2012-0995 (document 0004) · AD 2012-25-10

Manufacturer
Airbus
Type
All Operators Transmission
Number
A340-27A4181

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

ADs that cite it · 2

Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.

Also cited in 2 proposed ADs.

Text · 7OCR

This text is OCR from a scan. OCR can misread letters and numbers. © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0995; AD 2012-25-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'bd8ba17f65a427434037430dce4636f3a555ba48257183a8e565faaca2c341a9'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Page 1OCROpen in PDF

ALL OPERATORS TELEX - ALL OPERATORS TELEX SUBJECT: ATA 27 - SPOILER SERVO CONTROLS - LOSS OF THE HYDRAULIC LOCKING

FUNCTION OUR REF: AOT A340-27A4181 dated 04 January 2012

1. AIRCRAFT AFFECTED All A340-200 and A340-300 in-service aircraft fitted with MZ-type Spoiler Servo Controls (SSC), Part Number (PN) MZ4339390-12 or PN MZ4306000-12.

2. REFERENCED DOCUMENTATION

- Ref.1: Liebherr Component Maintenance Manual (CMM) 27-64-52 Figure 4 Item 210 - Blocking Valve

- Ref.2: Liebherr CMM 27-64-52 Figure 4 Item 140 - Maintenance operator Mechanism

- Ret.3: Liebherr CMM 27-64-52 Figure 4 Item 190 - Seal

- Ref.4: Airbus Service Bulletin (SB) A340-27-4115 - Flight Controls - Spoiler - Introduce operator mechanism cover EASA Airworthiness Directive (AD) 2008-0160 - Flight Controls - Spoiler Servo Control Maintenance Cover - Identification / Modification

- Ref. 6: FAA AD 2009-18-20

- Ref.7: Aircraft Maintenance Manual (AMM) Task 27-64-00-710-802 - Operational Test of the Hydraulic Locking Function on the Spoiler Servo

- Ref.8: AMM 27-64-52 PB 401 - Servo Control - Spoiler 2,3,4,5,6 - Removal / Installation

- Ref. 9: AMM 27-64-51 PB 401 - Servo Control - Spoiler 1 - Removal / Installation

- Ref. 10: Master Minimum Equipment List (MMEL) item 29-09-01 - HYD G(B) (Y) ELEC PUMP FAULT Alert, dated 16 December 2011

- Ref. 11: MMEL item 29-20-04 - Yellow Auxiliary Hydraulic power (Electrical Pump), dated 16 December 2011

- Ret. 12: Airbus Reporting Sheet RS-SEEL6-2011-686000

- Ref.13: Liebherr-Aerospace Information Notice reference AER/CS/1107-13

- Ref.14: Airbus Technical Follow Up (TFU) 27.64.00.013 - Spoiler SC MZ type - Loss Of Hydraulic Locking Function

3. REASON

3.1. FACTS Two operators have reported several spoilers not remaining in the retracted position after manual depressurization of the corresponding hydraulic circuit during test flights.

Subsequent checks on ground confirmed that, for each affected spoiler surface:

- The spoiler was fitted with one MZ-type SSC (PN MZ4339390-12 or PN MZ4306000-12)

- The maintenance operator mechanism of the SSC was confirmed in the 'o' (operation) position (hydraulic locking function operative).

Nevertheless, the spoiler surface could be manually extended.

3.2. SYSTEM DESCRIPTION Page 1

Page 2OCROpen in PDF

Each aircraft is fitted with six pairs of spoilers, identified from position 1 (inboard) to 6 (outboard).

Each SSC is controlled by a single flight control computer and supplied by one hydraulic circuit:

- Positions 1(13C1/13CS2) and 5 (17CS1/17C2) supplied by Green (G) circuit.

- Positions 2 (14cs1/14CS2) and 3 (15CS1/15CS2) supplied by Blue (B) Circsitions 4 (16CS1/16CS2) and 6 (18CS1/18CS2) supplied by Yellow (Y) circuit.

SSCs installed in position 1 are not interchangeable with the remaining 2 to 6 ssc positions since the length of the stroke is different.

the are at harack ice dunction ation revents the extension of the spoiler whose purpose is to ensure

- If the depressurization occurs when the spoiler is retracted, the SSC remains locked in position.

If the depressurization occurs when the spoiler is extended, the blocking valve allows the retraction under aerodynamic loads.

In addition to the blocking valve ref.1, the ssc is fitted with a maintenance operator mechanism ref.2, which allows the de-activation of the locking function for maintenance purposes.

During normal operation, the maintenance operator mechanism is set to the 'o' (Operation) position, and the hydraulic locking function is operative.

when the maintenance operator mechanism is set to the 'M' (Maintenance) position, the hydraulic locking function is de-activated, and the spoiler can be manually extended for maintenance purposes.

3.3. INVESTIGATIONS

3.3.1 SHOP FINDINGS The investigation of the affected SSCs at Liebherr revealed that the loss of the hydraulic locking function was due to an internal leakage caused by a sheared seal ref.3. This seal is installed at the left end of the blocking valve ref.1.

3.3.2 PREVIOUS MODIFICATION From 2008 to 2010, all MZ-type SSCs were modified to the current PN MZ4539390-12 (position 1) and PN MZ4306000-12 (position 2 to 6) as per ref.4 Airbus SB. This modification was mandated by ref.5 and ref. 6 ADs.

3.3.3 SUSPECTED ROOT CAUSE Most MZ-type SSCs were modified on-wing. During this on-wing modification, che rer.¿ maintenance operator mechanism was removed, allowing a possible untimely migration of the ref.1 blocking valve out of its groove.

It is suspected that this untimely migration is the root cause for the sheared ref. 3 seal events.

3.4. CONSEQUENCES Page 2

Page 3OCROpen in PDF

As long as the corresponding hydraulic circuit is pressurized, this failure as no impact on the operation of the spoilers.

in case of loss of the hydraulic locking function, the sSC is o longer able to remain in the retracted position in the event of a depressurization of the related hydraulic circuit. Therefore, the spoiler surface would extend up to the zero-hinge moment position, which mainly depends on the aircraft speed and on the Flap/Slat configuration.

This failure mode (internal leakage) cannot be detected by the flight control computers monitoring, and will remain as hidden until the ssociated hydraulic system is depressurized in flight. Should an untimely deflection in flight occur, this is announced to the crew via the ECAM varning F/CTL SPLR FAULT and the F/CTL Page on the System Display.

functional repliesure he testificate fail ki

3.5. AIM The aim of this AOT is to confirm the reliable functioning of the MZ-type sSCs currently installed on aircraft by means of a one-time test as per the new ref. 7 AMM task.

It is anticipated that this AOT will be rendered mandatory by an EASA AD.

4. REQUIRED ACTION

4.1. PLANNING AND MANPOWER The following corrective plan needs to be performed, as per paragraph 4.2, on all in-service affected aircraft:

- Within 90 days from receipt of this AOT:

* Identification of the concerned aircraft * Test of the MZ-type SSC(s)

- In case of findings:

Corrective actions to be accomplished before further flight on the SSCs related to the Blue hydraulic * Corrective actions to be accomplished within 24 months on the SSCs : circuit related to the Yellow and Green hydraulic systems

- Reporting within 30 days after accomplishment of the corrective actions Spare units are not affected by the requirements of this AOT, because the hydraulic locking function is tested after any shop repair prior to EASA Form 1 issuance.

consequen This Aot is only applicable to Mz-type ssc(s) already installed on in-service aircraft at the time of issuance of this AOT

- Aircraft which are not fitted with any MZ-type SSC are not affected by this AOT The application of this AOT requires:

- Five man-hours and one hour elapsed time for the application of the Page 3

Page 4OCROpen in PDF

ref.7 AMM task

- Additional three man-hours per SSC replacement.

4.2. DESCRIPTION

4.2.1. IDENTIFICATION/TEST OF AFFECTED AIRCRAFT within 90 days from receipt of this AOT:

1. Identify all aircraft fitted with at least one MZ-type SC. Note that:

- pN Mz 4339390-12 is installed in positions 1 onlY.

- PN MZ 4306000-12 is installed in positions 2 to 6.

The two following procedures are approved for the identification:

- Use the data from operator approved records.

- Read the data by visual inspection on aircraft.

on aircraft which are not fitted with any Mz-type ssc, no further action is required by this AOT.

L.At each position fitted with a MZ-type SSC, pertorm the test of the hydraulic locking function as per ref.7 AMM.

4.2.2 CORRECTIVE ACTIONS

1.On Blue hydraulic circuit, tor MZ-type SSC in position 2 and 3 (14CSI, 14CS2, 15CS1, 15CS2) :

- If the test is successful: No further action is required

- If the test fails: BEFORE FURTHER FLIGHT, interchange with a successfully tested unit from another circuit or replace with a spare part the faulty SSC(s), as per ref.8 AMM.

2.on Green hydraulic circuit, for Mz-type SSC in position 1 and 5 (13Cs1, 13CS2, 17CS1, 17CS2) :

- If the test is successful: No further action is required

- If the test fails, or if an unsuccessfully tested sSC is installed in position 5 after interchange with Blue circuit: within 24 months from AOT receipt, replace the faulty SSC(s) with a spare part as per ref.8 or ref.9 AMM.

3.on Yellow hydraulic circuit, for MZ-type SSC in position 4 and 6 (16CS1, 16CS2, 18CS1, 18CS2) :

- If the test is successful: No further action is required

- If the test fails, or if an unsuccessfully tested ssc is installed after interchange with Blue circuit:

replace the faulty ssC(s) with and ref. 11 MMEL.

* Once all the faulty MZ-type SSC(s) are removed from the Yellow hydraulic circuit:

Page 5OCROpen in PDF

- Dispatch capability with the Y EMP inoperative is restored as per ret.10 and ret.11 MMEL

- Report the retrofit completion as per paragraph 4.2.3 CAUTION: In order to prevent the installation of faulty units on nonaffected aircraft, only the interchange between positions of the same aircraft is acceptable.

ADVICE: Due to spare restriction (refer to 4.3):

- It is acceptable to interchange with a unit successfully tested from nother circuit of the same airplane, or to replace with a spare part che faulty SSC(s) identified in positions 2 and 3 (14CS1, 14CS2, 15CS1, 15CS2) .

acceptable to install or to keep installed unsuccessfully tested SC(s) in positioN 24339390-12 without hydraulic locking capability This approach allows:

per aircraft.

* up to six sSCs PN MZ4306000-12 without hydraulic locking capability per aircraft.

4.2.3 DATA REPORTING For all aircraft fitted with at least one M-type ssC, within 30 days after accomplishment of the test as per paragraph 4.2.1, report the test results to the Airbus contact given in paragraph 7 by means of the Reporting sheet Step 2 all aircraft fitted with at least one unsuccessfully tested ssc on the Yellow hydraulic Sc(s) of the Yellow circuit as per paragraph 4.2.4'7 by means of Reporting circuit, within 30 days after replacement of the faulty report the retrofit completion to the Airbus contact given in paragraph Sheet ref. 12.

4.3. MATERIAL - TOOLING No specific tooling is required for the inspection:

Concerning Liebherr-Aerospace is currently facing a difficult supply chain situation on SSC PN 1386x and 1387x -current production standard- due to the fire damage suffered by Liebherr-Aerospace manufacturing plant in Brazil (ref.13).

Airbus and Liebherr-Aerospace will increase the spares stock, planned to reach 60 units by June 2012. Nevertheless, the current number of available spares remains insufficient to provide advanced spare parts to all operators prior to application of this AOT.

ConsequentlY'+han six SScs PN MZ4306000-12 are found spare units will be supplied on AOG basis to operators if and only if more faulty on the same aircraft and no spares are available at the operator's warehouse.

Spare units have been positioned in Singapore, Europe and the USA in order to reduce the delivery lead-time. AOG orders should be addressed to:

Region: Europe, Africa, Middle East Llebherr-Aerospace Lindenberg GmbH (LLI) Phone: +49 8381 46 4868 Page 5

Page 6OCROpen in PDF

e-mail: spares.lli@liebherr.com 24 Hrs/7 Days Spares AOG Hotline: +49 171 852 7304 Region: Americas Liebherr-Aerospace Saline, Inc (LSL) Phone: +1 734 944 6378 e-mail: keith.turczyn@liebherr.com 24 Hrs/7 Days Spares AOG Hotline: +1 313 580 7262 Region: Asia-Pacific Liebherr-Aerospace Singapore Pte. Ltd. (LSI) Phone: +65 6265 2305 e-mail: charles.loke@liebherr.com 24 Hrs/7 Days Spares AOG Hotline: +65 9625 1607 According to the feedback as per paragraph 4.2.3, Airbus and Liebherr- Aerospace will establish a replacement plan of the faulty SSCs fitted on Green and Yellow hydraulic circuits.

The hurt the tu car and time of the faulty cs) in shop repair. loan units will be used to cover the spare Process will be monitored by Airbus and planned in accordance with operators' situation and availability.

5. FURTHER ACTION Follow-up of this AOT will be ensured by means of ref.14 TFU that will be issued by the end of January, 2012.

6. AOT APPROVAL The technical content of this AOT has been approved under EASA Design Organization Approval EASA.21J.031.

The content of this AOT is expected to be rendered mandatory by the Airworthiness Authorities.

7. REPORTING / ACKNOWLEDGEMENT Operators are requested to acknowledge receipt of this AOT within 48 hours after receipt to:

MIle Laetitia BONNET, SEEL Phone number: +33 (0)5 67 19 24 40 Fax number: +33 (0)5 61 93 32 73 E-mail: laetitia.bonnet@airbus.com This acknowledgement can be made through the Airbus RCSR office when available.

Questions about the technical content of this AOT, and inspection results, with or without findings, are to be sent to Airbus Customer Services, Engineering and Technical Support, attention of:

Mr. Daniel LOPEZ FERNANDEL'0? 04 52 SEEL6 Phone number: +33 (0)5 61 Fax number: +33 (0) 5 61 93 32 73 E-mail: daniel. lopez-fernandez@airbus.com Page 6

Page 7OCROpen in PDF

Best Regards, P. GOURDON VICE PRESIDENT A330/A340 PROGRAMME

CUSTOMER SERVICES DIRECTORATE organization ned to be added to the distribution, please advise your or if other people in your Airbus customer services contact accordingly.

AOT's attachments (if any) can be downloaded from Airbusworld via AirN@v / Engineering.