Copy · 737-53A1382-00--RB - BOEING · 227 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2019-0670, the docket of AD 2020-02-16. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'bb296ea55e6be421081a2726fe2bdb4004709894f5cd44cc6a0fc1ef92e80be4'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 121–132
Page 133Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727 TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 1: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 133 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 134OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 1, Configuration 1.

STA 1016 STA 727 STA STA 827 1016 S-1 S-14R - 001 0000000000 FRAME

UPPER SKIN

•LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE

INSPECTION AREA 2835335 FIGURE 2: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 134 of 227

Page 135Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727 TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 2: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 135 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 136OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 2-3, 11, Configuration 1.

STA 1016 STA 727

STA STA 727A 827 6 10000 STA 727 STA 908 1016 STA 7-S-1 00000 00000 S-14L FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2835336 FIGURE 3: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 136 of 227

Page 137Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 3: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 137 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 138OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 2, Configuration 1.

STA STA 827 727A

STA STA 1016 727 S-1 0000000000002000 - S-14R

FWD FRAME

UPPER SKIN

LOWER SKIN

TYPICAL CRACK

STRINGER-

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2835337 FIGURE 4: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 138 of 227

Page 139Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 4: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 139 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 140OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 4.

STA 1016 STA 727 A Dose STA 727A STA 1016 S-1 000000000 - S-14L FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2835338 FIGURE 5: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 140 of 227

Page 141Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 787 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 5: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 141 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 142OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 3, Configuration 1.

STA STA 747 727A STA 1016 000003000 - S-14R FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2835339 FIGURE 6: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 142 of 227

Page 143Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 747 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 6: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 143 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 144OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 4-5.

STA 1016 STA 727

STA STA 787 908

STA STA 1016 S-1 0000009000000 -S-14L FRAME

•

UPPER SKIN *LOWER SKIN

TYPICAL CRACK STRINGER•

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2835340 FIGURE 7: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 144 of 227

Pages 145–156 of 227