Copy · 737-53A1382-00--RB - BOEING · 227 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2019-0670, the docket of AD 2020-02-16. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'bb296ea55e6be421081a2726fe2bdb4004709894f5cd44cc6a0fc1ef92e80be4'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 133–144
Page 145Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 787 TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 7: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 145 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 146OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 3, Configuration 1.

STA 727

STA STA 847 747 STA 1016 S-1 0000000800000000 S-14R

FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851026 FIGURE 8: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 146 of 227

Page 147Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 747 TO STA 847 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 8: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 147 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 148OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 6, Configuration 2-3.

STA 1016 STA 727 STA 727G STA 1016 S-1

- S-14L FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2851021 FIGURE 9: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 148 of 227

Page 149Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 727G SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 9: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY

CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 149 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 150OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 4.

STA STA 787 727A STA 1016 S-1 900000000008000

- S-14R FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851027 FIGURE 10: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 150 of 227

Page 151Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 787 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 10: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 151 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 152OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 6, Configuration 1.

STA 1016 STA 727 STA 1016 S-1 0000 - S-14L WD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2851020 FIGURE 11: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 152 of 227

Page 153Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 11: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 153 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 154OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 4-5.

STA STA 908 787 STA 1016 000098000000 S-14R

FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK STRINGER•

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851028 FIGURE 12: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 154 of 227

Page 155Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 787 TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 12: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 155 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 156OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 7.

STA 1016 STA 727 i Does SZTA

SIZA STA 1016 S-1 000000 - S-14L WD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2851019 FIGURE 13: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 156 of 227

Pages 157–168 of 227