Page 157Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 13: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 157 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 158OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 6, Configuration 2-3.

STA 727 STA STA 1016 727

- S-1 000000000000200000 - S-14R FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851022 FIGURE 14: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 158 of 227

Page 159Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 727G SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 14: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 159 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 160OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 8.

STA 1016 STA 727

STA STA 727G 908

STA STA 727 1016 S-1 000000 - S-14L WD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2835341 FIGURE 15: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 160 of 227

Page 161Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727G TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 15: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 161 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 162OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 6, Configuration 1.

STA 727 STA 847

STA STA 1016 727

- S-1 000000000000200000 - S-14R FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851023 FIGURE 16: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 162 of 227

Page 163Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 847 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 16: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 163 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 164OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 9, Configuration 1; Group 10.

STA 1016 STA 727 <2b 1 e00l

STA STA 727A 827 STA 1016 000000000 - S-14L FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2835342 FIGURE 17: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 164 of 227

Page 165Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 17: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 165 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 166OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 7.

STA 727 0000 30 STA 806

STA STA 1016 727

- S-1 000000000000300000 - S-14R FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851024 FIGURE 18: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 166 of 227

Page 167Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 18: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 167 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 168OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 10.

STA 1016 STA 727 220 1 800

STA STA 727 1016 S-1 0000000000 • S-14L FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2850818 FIGURE 19: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 168 of 227

Pages 169–180 of 227