Copy · 737-53A1382-00--RB - BOEING · 227 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2019-0670, the docket of AD 2020-02-16. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'bb296ea55e6be421081a2726fe2bdb4004709894f5cd44cc6a0fc1ef92e80be4'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 157–168
Page 169Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 827 TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 19: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 169 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 170OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 8.

STA 727 000] 2)

STA STA 908 727G

STA STA 1016 727 S-1 000000000000000000 - S-14R FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851025 FIGURE 20: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 170 of 227

Page 171Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727G TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 20: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 171 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 172OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 1, Configuration 1.

STA 1016 STA 727 * 1000 STA 727

- S-1 000000000 - S-14L

FRAME WD

UPPER SKIN

LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE

• INSPECTION AREA 2851555 FIGURE 21: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 172 of 227

Page 173Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727 TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 21: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 173 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 174OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 9, Configuration 1.

STA 1016 STA 727 STA 847 27A

STA ISTA 1016 727

- S-1 0000000000000

- S-14R FRAME FWD

UPPER SKIN

LOWER SKIN

TYPICAL CRACK

STRINGER-

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2850935 FIGURE 22: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 174 of 227

Page 175Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 847 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 22: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 175 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 176OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 2-3, 11, Configuration 1.

STA 1016 STA 727

STA STA 727A 827 6 10000 STA 727 STA 908 1016 STA 7-S-1 00000 00000 S-14L FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2851556 FIGURE 23: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 176 of 227

Page 177Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with 737 NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 23: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 177 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 178OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 10.

STA 1016 STA 727 STA 787

STA ISTA 1016 727

- S-1 0000000000000

- S-14R FRAME FWD

UPPER SKIN

LOWER SKIN

TYPICAL CRACK

STRINGER-

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2850974 FIGURE 24: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 178 of 227

Page 179Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 787 SKIN - LAP SPLICEInspect1

(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fastener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.

Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure

9.

FIGURE 24: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 179 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 180OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 4.

STA 1016 STA 727 A Dose STA 727A STA 1016 S-1 000000000 - S-14L FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2851557 FIGURE 25: SECTION 46 - SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH

FREQUENCY EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 180 of 227

Pages 181–192 of 227