duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'f7f27dc5fbe91ea1ce39a2f3c3d35a40f3c38dd656327ec70c7043bbea7b8480' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'f7f27dc5fbe91ea1ce39a2f3c3d35a40f3c38dd656327ec70c7043bbea7b8480' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT
INTERCOSTAL TEE CLIP UPPER SKIN ~ OPEN LINER S-14L-
HOLE (TYPICAL) S-14
INTERCOSTAL STRAP
LOWER HINGE
FITTING FITTING• - FRAME WEB
SUPPORT TEE -
FITTING FASTENER
OUTER CHORD-
BEAR STRAP ' - FITTING S-15L
LOWER SKIN INBD A-A SURFACE HIGH FREQUENCY 0649267
EDDY CURRENT INSPECTION FIGURE 15: LEFT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE (SHEET 2 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 194 of 204
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(b)1-FRAME WEBInspect2
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the open hole for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
(b) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
FIGURE 15: LEFT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022 757-53A0120 RB 195 of 204 REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT This Figure applies only to: Group 3.
/ STA 1640 STA 1640 S-13R LOWER HINGE
INTERCOSTAL S-14R S-15R - S-16R - .....
FLOOR S-17R 2974757 FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION (SHEET 1 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 196 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT
INTERCOSTAL TEE CLIP
UPPER SKIN
- S-14R S-14 -
INTERCOSTAL STRAP
LOWER HINGE
FITTING FRAME WEB 1 LINER HOLE (TYPICAL)
• SUPPORT TEE
OUTER CHORD
FITTING- BEAR STRAP
• S-15R
LOWER SKIN INBD A-A
• GENERAL VISUAL 2974761
INSPECTION FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION (SHEET 2 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 197 of 204
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(a) Do a General Visual Inspection of the frame web on the aft side for existing liner hole.
FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022 757-53A0120 RB 198 of 204 REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT This Figure applies only to: Group 3.
/ STA 1640 STA 1640 S-13R - LOWER HINGE
INTERCOSTAL S-14R S-15R • S-16R - ............
FLOOR S-17R 2974759 FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE (SHEET 1 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 199 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT
INTERCOSTAL TEE CLIP
• UPPER SKIN S-14R S-14
INTERCOSTAL STRAP
LOWER HINGE
FITTING
FRAME WEB -
WITH ONE A - SUPPORT TEE
FASTENER OR
WITH TWO
FASTENERS
OUTER CHORD
FITTING BEAR STRAP S-15R
A-A LOWER SKIN
FITTING INBD
FASTENER
PLUGGED
LINER HOLE
• FITTING (TYPICAL)
INBD INBD FITTING
WITH ONE WITH TWO
FASTENER FASTENERS SURFACE HIGH FREQUENCY 2974762
EDDY CURRENT INSPECTION FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE (SHEET 2 OF 3) Original Issue: January 17, 2022 Export Controlled ECCN: 9E991 757-53A0120 RB Copyright © Unpublished Work - See page 1 for details. 200 of 204
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)(b)1-FRAME WEBInspect1
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener and the fastener in the plugged liner hole (if an adjacent second fastener exists) for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
(b) There can be 1 or 2 fastener hole locations to inspect.
FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022 757-53A0120 RB 201 of 204 REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT This Figure applies only to: Group 3.
STA 1640 STA 1640 S-13R 000 LOWER- HINGE
INTERCOSTAL S-14R - S-15R ...° S-16R - - oooooooo FLOOR S-17R 2975793 FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE (SHEET 1 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 202 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERT ALERT
INTERCOSTAL TEE CLIP
• UPPER SKIN
•S-14R OPEN LINER S-14 HOLE (TYPICAL)
INTERCOSTAL STRAP
LOWER HINGE
FITTING
FRAME WEB - FITTING
SUPPORT TEE
•
FITTING FASTENER
OUTER CHORD
FITTING BEAR STRAP S-15R
LOWER SKIN INBD A-A SURFACE HIGH FREQUENCY 2975796
EDDY CURRENT INSPECTION FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE (SHEET 2 OF 3) Original Issue: January 17, 2022 757-53A0120 RB Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details. 203 of 204
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(b)1-FRAME WEBInspect2
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the open hole for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
(b) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022 757-53A0120 RB 204 of 204 REQUIREMENTS BULLETIN 757-53A0120