REQUIREMENTS BULLETIN 767-57A0148

ALERT ALERT RADIUS 2 SO RADIUS FILLER "L" (5X7) RADIUS FILLER "I" ' FILLER "K" 201

FILLER J FILLER 'O' 5) RADIUS 2 € 10 RADIUS. FILLER "N" FWD FILLER "P"

5) 10) RADIUS 'FILLER "M" C-C The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for one side of the airplane.

Step Task Name Identification Qty More Data Locate FITTING, UNDER- 111T4020U7 1

WING LONGERON, LH Locate FITTING, INTERNAL 1

BATHTUB Locate SHIM, LAMINATED BACS40R016B018F 1 (a) Shim A.

Locate SHIM, LAMINATED BACS40R020C032F 1 (a) Shim B.

Locate SHIM, LAMINATED BACS40R014C022F 1 (a) Shim C.

Locate SHIM, LAMINATED BACS40R025C063F 2 (a) (p) Shim D.

Locate RADIUS FILLER 16 (b) Drill HOLE (c)(d) Drill and ream to final hole size.

Refer to the fastener code table.

FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 3 OF 8) Original Issue: October 10, 2024 767-57A0148 RB Export Controlled ECCN: 9E991 See page 1 for details 295 of 416

More DataQtyIdentificationNameTaskStep

(c)(d)(e) Drill and ream to final hole size. Refer to the fastener code table.

42-HOLEDrill4

(f)16-RADIUS FILLERRemove / Keep5 Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep

(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep -1-FITTING, INTERNAL

BATHTUB Remove / Keep -1111T4020U7FITTING, UNDER-

WING LONGERON, LH Remove / Keep Clean and deburr all structure.

--STRUCTUREClean/Deburr

(g)1111T4020U7FITTING, UNDER-

WING LONGERON, LH Install (New)6

(h)12-RADIUS FILLERInstall (Kept)7

(i) Refer to the fastener code table.

34-FASTENERInstall (New)8

(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9

(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)

(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)

(j)1-FITTING, INTERNAL

BATHTUB Install (Kept) -1-TEMPORARY TEN-

SION BOLT Install (New)

(k)4-RADIUS FILLERInstall (Kept)10

(l) Refer to the fastener code table.

8-FASTENERInstall (New)11 FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 4 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 296 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataQtyIdentificationNameTaskStep -1-TEMPORARY TEN-

SION BOLT Remove12 Ream and deburr the tension bolt hole to final hole size.

Refer to the fastener code table.

1-HOLEReam

(l) Refer to the fastener code table.

1-FASTENERInstall (New)

(m)(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13

(l)3-FASTENERInstall (New)14

(n)5 OzBMS 5-45SEALANTApply15

(o)5 OzBMS 5-95SEALANTApply16

(a) Peel the shim as required to get a maximum gap of 0.005 inch.

(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from removal.

(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.

(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if open hole HFEC confirms crack-free condition.

(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767- 300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.

(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at each location for re-installation.

(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron fitting. Refer to SOPM 20-50-19 as an accepted procedure.

(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation from removal.

(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM 20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767- 300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.

Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are common to the underwing longeron fitting.

(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.

(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.

(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.

(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.

FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 5 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 297 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataQtyIdentificationNameTaskStep

(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted procedure.

(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20- 50-19 as an accepted procedure.

(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s) based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate number of shim(s) as necessary.

The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.

A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the number of fasteners necessary for this figure.

More DataHole DiaQtyIdentificationNameCode First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING HD A --28BACC30BH8COLLAR Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING HD --28BACC30AC8COLLAR First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING HD B ---BACC30BH10COLLAR Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING HD --11BACC30AC10COLLAR FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 6 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 298 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataHole DiaQtyIdentificationNameCode First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING HD C --1BACC30BH12COLLAR Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING HD --1BACC30AC12COLLAR First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD --1BACC30BH14COLLAR Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT --1BACC30AC14COLLAR First oversize fastener (if 5/16 inch hi-lok was installed.)

0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING HD E --1BACC30BH10COLLAR Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING HD --1BACC30AC10COLLAR First oversize fastener (if 5/16 inch bolt and nut was installed.)

0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD Under the bolt head.-1BACW10BP51CDWASHER, PLAIN Under the nut.-1BACW10BP51DPWASHER, PLAIN Torque nut to 243 to 258 inch lbs.

-1BACN10HR5CDNUT First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF Under the bolt head.-3BACW10BP101CDWASHER, PLAIN Under the nut.-3BACW10BP101DPWASHER, PLAIN Torque nut to 1843 to 1957 inch lbs.

-3BACN11Z10CDNUT Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT Under the bolt head.-3BACW10BP102CDWASHER, PLAIN Under the nut.-3BACW10BP102DPWASHER, PLAIN Torque nut to 1843 to 1957 inch lbs.

-3BACN11Z10CDNUT FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 7 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 299 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataHole DiaQtyIdentificationNameCode First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND

COUNTERSUNK Self-aligning washer set.

Under the nut.

-1BACW10CA91CVWASHER Self-aligning washer set.

Under the nut.

-1BACW10CA10CCWASHER Between nut and selfaligning washer, for grip length adjustment.

-1BACW10BP91DPWASHER, PLAIN Torque nut to 1746 to 1854 inch lbs.

-1BACN10HR9CDNUT FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 8 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 300 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

Page 7OCROpen in PDF

REQUIREMENTS BULLETIN 767-57A0148

ALERT ALERT This Figure applies only to: Group 1, 3.

STA FUSELAGE 783.04

FRONT SPAR SKIN UPPER DRAG

SPLICE ANGLE

UNDERWING LOWER DRAG

LONGERON SPLICE ANGLE

FITTING

UNDERWING LONGERON FITTING 3054597 FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 1 OF 8) Original Issue: October 10, 2024 Export Controlled ECCN: 9E991 767-57A0148 RB See page 1 for details 301 of 416

Page 8OCROpen in PDF

REQUIREMENTS BULLETIN 767-57A0148

ALERT ALERT

SEAL RETAINER FRONT B BATHTUB FITTING U€9 INTERNAL SPAR B SHIM "A" 059 UNDERWING 1G) ·16 SHIM "C" O€

LONGERON FITTING STA

776.21 + + SHIM "B" ( 1 8 LOCATIONS ® A 126

UNDERWING LONGERON FITTING 3 LOCATIONS

RADIUS A-A FWD

FILLER 'B' RADIUS

FILLER'A' + - RADIUS FILLER "B" 34 LOCATIONS RADIUS FILLER "C" 22 RADIUS FILLER "D' SHIM "D"

5) (2 LOCATIONS) 1 € 13

5) 10 RADIOS ' FILLER "A" 5 7 RADES 'FILLER "E" RADIUS FILLER "F' FILLER "H" RADIUS FILLER "G" B-B FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 2 OF 8) Original Issue: October 10, 2024 767-57A0148 RB Export Controlled ECCN: 9E991 See page 1 for details 302 of 416

Page 9OCROpen in PDF

REQUIREMENTS BULLETIN 767-57A0148

ALERT ALERT RADIUS RADIUS FILLER "K" RADIUS FILLER "L" RADIUS FILLER "I" FILLER "J" (2) 5)

RADIUS RADIUS FILLER "P" FILLER "O" FILLER "N" RADIUS 2E10 FWD 10 RADIUS C-C FILLER "M" The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for one side of the airplane.

Step Task Name Identification Qty More Data 1 Locate FITTING, UNDER- 111T4020U8 1

WING LONGERON, RH Locate FITTING, INTERNAL 1

BATHTUB Locate SHIM, LAMINATED BACS40R016B018F 1 (a) Shim A.

Locate SHIM, LAMINATED BACS40R020C032F 1 (a) Shim B.

Locate SHIM, LAMINATED BACS40R014C022F 1 (a) Shim C.

Locate SHIM, LAMINATED BACS40R025C063F 2 (a) (p) Shim D.

2 Locate RADIUS FILLER 16 (b) Drill HOLE 3 (c)(d) Drill and ream to final hole size.

Refer to the fastener code table.

FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T402008 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 3 OF 8) Original Issue: October 10, 2024 Export Controlled ECCN: 9E991 767-57A0148 RB See page 1 for details 303 of 416

More DataQtyIdentificationNameTaskStep

(c)(d)(e) Drill and ream to final hole size. Refer to the fastener code table.

42-HOLEDrill4

(f)16-RADIUS FILLERRemove / Keep5 Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep

(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep -1-FITTING, INTERNAL

BATHTUB Remove / Keep -1111T4020U8FITTING, UNDER-

WING LONGERON, RH Remove / Keep Clean and deburr all structure.

--STRUCTUREClean/Deburr

(g)1111T4020U8FITTING, UNDER-

WING LONGERON, RH Install (New)6

(h)12-RADIUS FILLERInstall (Kept)7

(i) Refer to the fastener code table.

34-FASTENERInstall (New)8

(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9

(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)

(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)

(j)1-FITTING, INTERNAL

BATHTUB Install (Kept) -1-TEMPORARY TEN-

SION BOLT Install (New)

(k)4-RADIUS FILLERInstall (Kept)10

(l) Refer to the fastener code table.

8-FASTENERInstall (New)11 FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 4 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 304 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataQtyIdentificationNameTaskStep -1-TEMPORARY TEN-

SION BOLT Remove12 Ream and deburr the tension bolt hole to final hole size.

Refer to the fastener code table.

1-HOLEReam

(l) Refer to the fastener code table.

1-FASTENERInstall (New)

(p)(m) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13

(l)3-FASTENERInstall (New)14

(n)5 OzBMS 5-45SEALANTApply15

(o)5 OzBMS 5-95SEALANTApply16

(a) Peel the shim as required to get a maximum gap of 0.005 inch.

(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from removal.

(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.

(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if open hole HFEC confirms crack-free condition.

(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767- 300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.

(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at each location for re-installation.

(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron fitting. Refer to SOPM 20-50-19 as an accepted procedure.

(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation from removal.

(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM 20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767- 300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.

Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are common to the underwing longeron fitting.

(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.

(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.

(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.

(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.

FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND

INTERNAL BATHTUB FITTING - INSTALLATION (SHEET 5 OF 8) Export Controlled ECCN: 9E991 See page 1 for details Original Issue: October 10, 2024 767-57A0148 RB 305 of 416 REQUIREMENTS BULLETIN 767-57A0148

ALERTALERT

More DataQtyIdentificationNameTaskStep

(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted procedure.

(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20- 50-19 as an accepted procedure.

(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s) based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate number of shim(s) as necessary.

The flag note numbers shown below agree with the numbers shown in the flag symbols in the figure.

More DataFlag Note Install head on near side.1 Install head on far side.2 The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.

A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the number of fasteners necessary for this figure.

More DataHole DiaQtyIdentificationNameCode First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING HD A --28BACC30BH8COLLAR Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING HD --28BACC30AC8COLLAR FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND