On this page
ADs that cite it · 1
Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.
Also cited in 1 proposed AD.
Text · 12OCR
This text is OCR from a scan. OCR can misread letters and numbers. © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2010-0550; AD 2010-20-19 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '8cb44861c1f87b02f12276519b89aa8958ab7a2040c93597fd362b2f71d3670e' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '8cb44861c1f87b02f12276519b89aa8958ab7a2040c93597fd362b2f71d3670e' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
BOMBARDIER
SERVICE BULLETIN
REVISION TRANSMITTAL SHEET CL-600-2B19 Canadair Regional Jet (CRJ) Aircraft ALERT SERVICE BULLETIN A601R-24-120 SUBJECT: Electrical Power System - Emergency AC Power Generation System - Special Detailed Inspection of the Air Driven Generator (ADG) Strut This page transmits:
Revision C of Alert Service Bulletin A601R-24-120, pages 1 thru 9, dated Apr 20/2009.
The changes in this revision have no effect on aircraft that have incorporated a previous issue of this service bulletin.
Reason:
Revised Planning Information, paragraph 1., to:
Change the Hamilton Sunstrand service bulletin revision.
This revision also includes small editorial changes that do not have an effect on the technical content.
Instructions:
Discard the copy of Alert Service Bulletin A601R-24-120, Revision B, dated Dec 07/2006. Replace with the copy attached.
Service Bulletin History:
Initial issue, dated Apr 20/2005.
Revision A, dated Dec 01/2005.
Revision B, dated Dec 07/2006.
Apr 20/2009 SB A601R-24-120 Page 1 of 1
BOMBARDIER
ALERT SERVICE BULLETIN Technical Publications THIS SERVICE BULLETIN IS SENT TO EACH OPERATOR. IF THE OPERATOR HAS LEASED AIRCRAFT, THIS SERVICE BULLETIN MUST BE SENT TO THE LESSEE. IF THE OPERATOR
HAS SOLD AIRCRAFT OR TRANSFERRED SPARES IN THE LAST SIX MONTHS, THIS SERVICE
BULLETIN MUST BE SENT TO THE NEW OWNER, UNLESS CONFIRMATION WAS RECEIVED
THAT BOMBARDIER REGIONAL AIRCRAFT DIVISION HAS INCLUDED THE NEW OPERATOR ON THE DISTRIBUTION LIST.
ATA SYSTEM: 24-23 NUMBER: A601R-24-120 SUBJECT: Electrical Power System - Emergency AC Power Generation System - Special Detailed Inspection of the Air Driven Generator (ADG) Strut
1. PLANNING INFORMATION A. Effectivity
(1) Aircraft Affected:
Service Bulletin: CL-600-2B19 Canadair Regional Jet (CRJ) Aircraft Serial Numbers 7305 thru 7990, 8000 thru 8051.
NOTE: The inspection of this service bulletin was incorporate on Aircraft Serial Number 8020 thru 8051 after Certificate of Airworthiness and before delivery.
Production: There is no production effectivity.
NOTE: The instructions in this Service Bulletin are only applicable to the systems and parts installed at the time of delivery of the aircraft or as changed by Bombardier Aerospace Service Bulletin(s). Before you do this bulletin, examine all STC, STA or equivalent action changes to make sure this bulletin can be completed.
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 1 of 9
ALERT SERVICE BULLETIN A601R-24-120 B. Reason
(1) Condition It is possible for a crack to start on the aft area of the strut assembly of the ADG.
(2) Evidence During an inspection of the ADG, damage was found on the strut of one ADG in the area adjacent to the generator.
(3) Objective/Benefit This service bulletin gives instructions to do a special detailed inspection of the dry ADG and, if necessary, to replace the ADG.
C. Description Circuit breakers are opened and tagged. The dry ADG is lowered. The Hamilton Sundstrand service bulletin ERPS10AG-24-3 is done. If damage is found, the ADG is replaced and the damaged ADG is sent to Hamilton Sundstrand. The dry ADG is retracted to the stow position. If the ADG was replaced, a dry ADG clearance checks and functional test of the dry ADG is done. The circuit breakers are closed and the aircraft is returned to service.
D. Compliance Alert Service Bulletin. Bombardier Aerospace recommends that this service bulletin be done no more than 1000 flight hours from the release date on this service bulletin unless otherwise directed by the airworthiness authority of the operator.
E. Approval The technical content of this service bulletin has been approved under the authority of the TCCA Design Approval Organization No: DAO #93-Q-02.
F. Manpower The man hours given below are an estimate for direct labor done by an experienced crew on an aircraft prepared for maintenance.
This estimate does not include the time necessary for:
- Administrative tunctions such as planning, liaison, familiarization, and report writing.
- Non productive elapsed time such as rest time, having meals, and crew shift changes.
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 2 of 9
ALERT SERVICE BULLETIN A601R-24-120
- Elapsed time such as for paint to dry, sealant to cure, and fuel tank venting.
- Preparation for modification (unless specified in the accomplishment instructions) such as cleaning and getting parts, tools, consumables, and ground equipment.
- Quality assurance inspections, troubleshooting and/or correction of discrepancies found when a task is done.
- All other activities that are not considered by Bombardier Aerospace as directly related to the accomplishment of this procedure.
It will take an estimated 0.5 man-hours to complete this service bulletin. The man-hours are divided as shown in the table that follows:
TASK MAN-HOURS
(1) Job Set-Up 0.25
(2) Procedure N/A
(3) Test N/A
(4) Job Close-Out 0.25 NOTE: This estimate does not include the man- hours necessary to do Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
NOTE: The man-hours to replace the ADG, do the functional test and the clearance checks are not shown in the table. If it is necessary to replace the ADG, add
4.0 man-hours to replace the ADG and to do the related tests.
G. Material - Price and Availability Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
H. Tooling - Price and Availability Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
Weight and Balance Not changed.
J. Electrical Load Data Not changed.
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 3 of 9
ALERT SERVICE BULLETIN A601R-24-120 K. References Restriction and/or Special Instruction (RSI) C-A114, Revision E.
Hamilton Sundstrand Service Bulletin ERPS10AG-24-3, Revision 3, dated Mar 12/09.
Aircraft Maintenance Manual, CSP A-001, Revision 34.
For Bombardier Aerospace reference only: PCA 4800.
Other Publications Affected Aircraft Maintenance Manual (AMM), CSP B-001.
M. Relationship Chart Not applicable.
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 4 of 9
ALERT SERVICE BULLETIN A601R-24-120
2. ACCOMPLISHMENT INSTRUCTIONS A. Job Set-Up Reference Information
REFERENCE AMM 24-00-00-910-801 AMM 24-23-01-020-803 AMM 24-23-01-420-801 AMM 24-23-01-720-803 AMM 24-23-01-840-804 AMM 24-23-01-840-805 AMM 24-23-28-220-801 AMM 29-00-00-910-801
DESIGNATION Electrical/electronic Safety Precautions Removal of the Dry ADG Installation of the Dry ADG Functional Test of the Dry ADG Manual Lowering of the Dry ADG Retraction of the Dry ADG after Deployment Dry ADG Clearance Checks Hydraulic Safety Precautions WARNING: OBEY ALL THE HYDRAULIC SAFETY PRECAUTIONS WHEN YOU DO
WORK ON ANY HYDRAULIC SYSTEM OR ON A HYDRAULIC SYSTEM COMPONENT. IF YOU DO NOT OBEY THE SAFETY PRECAUTIONS,
YOU CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Obey all the hydraulic safety precautions (Refer to AMM 29-00-00-910-801) WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO
MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. IF YOU DO NOT OBEY THE SAFETY PRECAUTIONS,
INJURIES TO PERSONS AND/OR DAMAGE TO THE EQUIPMENT CAN OCCUR.
(2) Obey all the electrical/electronic safety precautions (Refer to AMM 24-00-00-910-801).
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 5 of 9
ALERT SERVICE BULLETIN A601R-24-120
(3) Open, safety, and tag the circuit breakers that follow:
CB PANEL CB NO. NAME ZONE CBP -2 N6 ADG DEPLOY CONT AUTO 222 CBP -2 N7 ADG DEPLOY CONT MAN 222 CBP -5 B10 ADG AUTO 311 CBP -5 B11 ADG MAN 311
(4) If not deployed, manually lower the dry ADG (Refer to AMM 24-23-01-840-804).
B. Procedure Refer to Figure 1.
(1) Do the Hamilton Sundstrand Service Bulletin ERPS10AG-24-3 (Fluorescent Penetrant Inspection).
(2) If a crack is found do as follows:
(a) Remove the dry ADG (Refer to AMM 24-23-01-020-803).
(b) Return the damaged part to the address below:
Hamilton Sundstrand 4747 Harrison Avenue P.O. Box 7002 Rockford, IL 61125 Attention: Repair Administration Mail Stop 265-6 Phone: 815-226-6849 Fax: 815-226-6826
(c) Install the new dry ADG (Refer to AMM 24-23-01-420-801).
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 6 of 9
ALERT SERVICE BULLETIN A601R-24-120 C. Job Close-Out
(1) If the dry ADG was not replaced, do as follows:
(a) Retract the dry ADG to the stowed position (Refer to AMM 24-23-01-840-805).
(b) Remove the tags and close the circuit breakers that follow:
CB PANEL CB NO. NAME ZONE CBP -2 N6 ADG DEPLOY CONT AUTO 222 CBP -2 N7 ADG DEPLOY CONT MAN 222 CBP -5 B10 ADG AUTO 311 CBP -5 B11 ADG MAN 311
(2) If the dry ADG was replaced do as follows:
(a) Do the dry ADG clearance checks (Refer to AMM 24-23-28-220-801).
(b) Remove the tags and close the circuit breakers that follow:
CB PANEL CB NO. NAME ZONE CBP -2 N6 ADG DEPLOY CONT AUTO 222 CBP -2 N7 ADG DEPLOY CONT MAN 222 CBP —5 B10 ADG AUTO 311 CBP -5 B11 ADG MAN 311
(c) Do the functional test of the dry ADG (Refer to AMM 24-23-01-720-803).
(3) Remove all tools, equipment, and unwanted materials from the work area.
(4) When this service bulletin is completed, make this entry in the applicable logbook(s): "Alert Service Bulletin A601R-24-120, Revision C, Electrical Power System - Emergency AC Power Generation System - Special Detailed Inspection of the Air Driven Generator (ADG) Strut, incorporated."
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 7 of 9
ALERT SERVICE BULLETIN A601R-24-120
AIR DRIVEN
GENERATOR rsb601r24120_001.dg, om, 06/04/05 Air Driven Generator (ADG) Figure 1 Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 8 of 9
ALERT SERVICE BULLETIN A601R-24-120
3. MATERIAL INFORMATION A. Kit Information None.
B. Rotable Information Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
C. Consumable Information For a list of consumables, refer to the different tasks and the Hamilton Sundstrand Service Bulletin given as references in this service bulletin.
D. Special Tools and Equipment For a list of special tools and equipment, refer to the different tasks and the Hamilton Sundstrand Service Bulletin given in this references in this service bulletin.
E. Disposition of Parts Not applicable.
Apr 20/2005 S.B. A601R-24-120 Revision C, Apr 20/2009 Page 9 of 9
BOMBARDIER
SERVICE BULLETIN EVALUATION FORM/COMPLIANCE SHEET (YOUR IDEAS WILL HELP US PROVIDE BETTER BULLETINS) SERVICE BULLETIN: 601R-24-120 ISSUE: C
STRONGLY DISAGREE NEUTRAL AGREE STRONGLY
DISAGREE AGREE
• Instructions to do the Service Bulletin were accurate.
Comments:
• Illustration(s), figure(s), picture(s) and/or kit drawing(s) were helpful to carry out instructions.
Comments:
• If a parts kit was required, did the kit contents received agree with the contents listed in the bulletin?
Comments:
• Aircraft hands-on work was accomplished in estimated time.
Comments:
• Overall, I was satisfied with this Service Bulletin.
Comments:
PLEASE SUPPLY US WITH THE FOLLOWING DATA AND FAX TO (450) 476-7300:
OPERATOR: NAME (Please print) SERVICE CENTER: TELEPHONE:
AIRCRAFT SERIAL NO.: FACSIMILE:
DATE OF SB
INCORPOARTION
THANK YOU FOR ANSWERING THIS EVALUATION FORM
UPON COMPLETION OF THIS EVALUATION FORM/COMPLIANCE SHEET, FAX TO 450-476-7300
No text on this page: it may be a figure. Open the PDF to see it.