TextOCR
This text is OCR from a scan. OCR can misread letters and numbers.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '38b330c8c3effe35b4ca94e410443151324990f959aa1c6e862d7b0861dbc59c' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '38b330c8c3effe35b4ca94e410443151324990f959aa1c6e862d7b0861dbc59c' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
BOMBARDIER
SERVICE BULLETIN
REVISION TRANSMITTAL SHEET CL-600-2C10, CL-600-2D15 and CL-600-2D24
CANADAIR REGIONAL JET (CRJ) AIRCRAFT ALERT SERVICE BULLETIN A670BA-24-020 SUBJECT: Electrical Power System - Emergency AC Power Generation System - Specia Detailed Inspection of the Air Driven Generator (ADG) Stru This page transmits:
Revision C of Alert Service Bulletin A670BA-24-020, pages 1 thru 9, dated April 20/2009.
The changes in this revision have no effect on aircraft that have incorporated a previous issue of this service bulletin.
Reason:
Revised Planning Information, paragraph 1., to:
Change the Hamilton Sundstrand service bulletin revision to 3.
This revision also includes small editorial changes that do not have an effect on the technical content.
Document Instructions:
Discard the copy of Alert Service Bulletin A670BA-24-020, Revision B, dated Dec 07/2006. Replace with the copy attached.
Service Bulletin History:
Initial issue, dated Apr 20/2005.
Revision A, dated May 17/2005.
Revision B, dated Dec 07/2006.
Apr 20/2009 S.B. A670BA-24-020 Page 1 of 1
BOMBARDIER
ALERT SERVICE BULLETIN Technical Publications THIS SERVICE BULLETIN IS SENT TO EACH OPERATOR. IF THE OPERATOR HAS LEASED AIRCRAFT, THIS SERVICE BULLETIN MUST BE SENT TO THE LESSEE. IF THE OPERATOR HAS SOLD AIRCRAFT OR
TRANSFERRED SPARES IN THE LAST SIX MONTHS, THIS SERVICE BULLETIN MUST BE SENT TO THE
NEW OWNER, UNLESS CONFIRMATION WAS RECEIVED THAT BOMBARDIER COMMERCIAL AIRCRAFT DIVISION HAS INCLUDED THE NEW OPERATOR ON THE DISTRIBUTION LIST.
ATA SYSTEM: 24-23 NUMBER: A670BA-24-020 SUBJECT: Electrical Power System - Emergency AC Power Generation System - Special Detailed Inspection of the Air Driven Generator (ADG) Strut
1. PLANNING INFORMATION A. Effectivity
(1) Aircraft Affected:
Service Bulletin: CL-600-2C10 Canadair Regional Jet (CRJ) Aircraft Serial Numbers 10003 thru 10260.
NOTE: The inspection in this service bulletin was done on Aircraft Serial Numbers 10003 and 10201 thru 10260 after Certificate of Airworthiness and before delivery.
Production: There is no production effectivity Service Bulletin: CL-600-2D15 Canadair Regional Jet (CRJ) and CL-600-2D24 Canadair Regional Jet (CRJ) Aircraft Serial Numbers 15001 thru 15106 NOTE: The inspection in this service bulletin was done on Aircraft Serial Numbers 15031 thru 15106 after Certificate of Airworthiness and before delivery.
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 1 of 9
ALERT SERVICE BULLETIN A670BA-24-020 Production: There is no production effectivity.
NOTE: The instructions in this Service Bulletin are only applicable to the systems and parts installed at the time of delivery of the aircraft or as changed by Bombardier Aerospace Service Bulletin(s). Before you do this bulletin, examine all STC, STA or equivalent action changes to make sure this bulletin can be completed.
B. Reason
(1) Condition It is possible for a crack to start on the aft area of the strut assembly of the ADG.
(2) Evidence During an inspection of the ADG, damage was found on the strut of one ADG in the area adjacent to the generator.
(3) Objective/Benefit This service bulletin gives instructions to do a special detailed inspection of the ADG and, if necessary, to replace the ADG.
C. Description Circuit breakers are opened and tagged. The ADG is lowered. The Hamilton Sundstrand service bulletin ERPS10AG-24-3 is done. If damage is found, the ADG is replaced and the damaged ADG is sent to Hamilton Sundstrand. The ADG Is retracted to the stow position. If the ADG was replaced, an ADG clearance checks and functional test of the ADG is done. The circuit breakers are closed.
D. Compliance Alert Service Bulletin.
Bombardier Aerospace recommends that this service bulletin be done no more than 1000 flight hours from the release date on this service bulletin unless otherwise directed by the airworthiness authority of the operator.
E. Approval The technical content of this Service Bulletin has been approved under the authority of the TCCA Design Approval Organization No: DAO #93-Q-02.
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 2 of 9
ALERT SERVICE BULLETIN A670BA-24-020 F. Manpower The man-hours given below are an estimate for direct labor done by an experienced crew on an aircraft prepared for maintenance.
This estimate does not include the time necessary for:
- Administrative tunctions such as planning, liaison, familiarization, and report writing.
- Non productive elapsed time such as rest time, having meals, and crew shift changes.
- Elapsed time such as for paint to dry, sealant to cure, and fuel tank venting.
- Preparation for modification (unless specified in the accomplishment instructions) such as cleaning and getting parts, tools, consumables, and ground equipment.
- Quality assurance inspections, troubleshooting and/or correction of discrepancies found when a task is done.
- All other activities that are not considered by Bombardier Aerospace as directly related to the accomplishment of this procedure.
It will take an estimated 0.5 man-hours to complete this service bulletin. The man-hours are divided as shown in the table that follows:
TASK MAN-HOURS
(1) Job Set-Up 0.25
(2) Procedure N/A
(3) Test N/A
(4) Job Close-Out 0.25 NOTE: This estimate does not include the man-hours necessary to do Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
NOTE: The man-hours to replace the ADG, do the functional test and the clearance checks are not shown in the table. If it is necessary to replace the ADG, add 4.0 man-hours to replace the ADG and to do the related Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 3 of 9
ALERT SERVICE BULLETIN A670BA-24-020 G. Material - Price and Availability Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
H. Tooling - Price and Availability Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
I. Weight and Balance Not changed.
J. Electrical Load Data Not changed.
K. References
- Restriction and/or Special Instruction (RSI), C-24-0455-00, Revision F.
- Aircraft Maintenance Manual (AMM), CSP B-001, Revision 16.
- Hamilton Sundstrand Service Bulletin ERPS10AG-24-3, Revision 3, dated Mar 12/09.
- For Bombardier Aerospace reference only: PCA 71702.
L. Other Publications Affected
- Aircraft Maintenance Manual (AMM), CSP B-001.
M. Relationship Chart Not applicable.
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 4 of 9
ALERT SERVICE BULLETIN A670BA-24-020
2. ACCOMPLISHMENT INSTRUCTIONS A. Job Set-Up
(1) Reference Information
REFERENCE DESIGNATION AMM 12-00-00-867-801 Standard Aircraft Configuration for Maintenance AMM 24-00-00-910-801 Electrical/Electronic Safety Precautions AMM 24-23-01-000-801 Removal of the ADG AMM 24-23-01-220-801 Clearance Checks of the ADG AMM 24-23-01-400-801 Installation of the ADG AMM 24-23-01-720-801 Functional Test of the ADG (On-Ground) AMM 24-23-01-840-801 Extension of the ADG AMM 24-23-01-840-802 Retraction of the ADG AMM 29-00-00-910-801 Hydraulic Safety Precautions
(2) Make sure that the aircraft is in standard configuration for maintenance (AMM 12-00-00-867-801).
WARNING: OBEY ALL THE HYDRAULIC SAFETY PRECAUTIONS WHEN
YOU DO WORK ON ANY HYDRAULIC SYSTEM OR ON A HYDRAULIC SYSTEM COMPONENT. IF YOU DO NOT OBEY
THE SAFETY PRECAUTIONS, YOU CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(3) Obey all the hydraulic safety precautions (AMM 29-00-00-910-801).
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO
MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. YOU CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(4) Obey all the electrical/electronic safety precautions (AMM 24-00-00-910-801).
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 5 of 9
ALERT SERVICE BULLETIN A670BA-24-020
(5) Open, safety, and tag the circuit breakers that follow:
CB-PANEL CB NO. NAME CBР-2 N6 ADG DEPLOY AUTO CBP-2 N7 ADG DEPLOY MAN
(6) If not deployed, do an extension of the ADG (AMM 24-23-01-840-801).
B. Procedure Refer to Figure 1.
(1) Do the Hamilton Sundstrand Service Bulletin ERPS10AG-24-3 (Fluorescent Penetrant Inspection).
(2) If a crack is found do as follows:
(a) Remove the ADG (AMM 24-23-01-000-801).
(b) Return the damaged part to the address below:
Hamilton Sundstrand 4747 Harrison Avenue P.O. Box 7002 Rockford, IL 61125 Attention: Repair Administration Mail Stop 265-6 Phone: 815-226-6849 Fax: 815-226-6826
(c) Install the new ADG (AMM 24-23-01-400-801).
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 6 of 9
ALERT SERVICE BULLETIN A670BA-24-020
AIR DRIVEN
GENERATOR rsb601/24120 001.da. om. 06/04/05 Detailed Inspection on the ADG Figure 1 Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 7 of 9
ALERT SERVICE BULLETIN A670BA-24-020 C. Job Close-Out
(1) If the ADG was not replaced do as follows:
(a) Do a retraction of the ADG (AMM 24-23-01-840-802).
(b) Remove the tags and close the circuit breakers that follow:
CB-PANEL CB NO. NAME CBP-2 N6 ADG DEPLOY AUTO CBP-2 N7 ADG DEPLOY MAN
(2) If the ADG was replaced do as follows:
(a) Do the ADG clearance checks (AMM 24-23-01-220-801).
(b) Remove the tags and close the circuit breakers that follow:
CB-PANEL CB NO. NAME CBP-2 N6 ADG DEPLOY AUTO CBP-2 N7 ADG DEPLOY MAN
(c) Do the functional test of the ADG (AMM 24-23-01-720-801).
(3) Remove all tools, equipment, and unwanted materials from the work area.
(4) When this service bulletin is completed, make this entry in the applicable logbook(s) as follows: "Alert Service Bulletin A670BA-24-020, Revision C, Electrical Power System - Emergency AC Power Generation System - Special Detailed Inspection of the Air Driven Generator (ADG) Strut, incorporated."
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 8 of 9
ALERT SERVICE BULLETIN A670BA-24-020
3. MATERIAL INFORMATION A. Kit Information None.
B. Rotable Information Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
C. Consumable Information For a list of consumables, refer to the different tasks and the Hamilton Sundstranc Service Bulletin given as references in this service bulletin.
D. Special Tools and Equipment For as of Sed lian dein this refer toes fence sand the Hamilton E. Disposition of Parts Not applicable.
Apr 20/2005 S.B. A670BA-24-020 Revision C, Apr 20/2009 Page 9 of 9
BOMBARDIER
SERVICE BULLETIN EVALUATION FORM/COMPLIANCE SHEET (YOUR IDEAS WILL HELP US PROVIDE BETTER BULLETINS) SERVICE BULLETIN: A670BA-24-020 ISSUE: C
STRONGLY DISAGREE NEUTRAL AGREE STRONGLY
DISAGREE AGREE
• Instructions to do the Service Bulletin • were accurate.
Comments:
• Illustration(s), figure(s), picture(s) and/or kit drawing(s) were helpful to carry out instructions.
Comments:
• If a parts kit was required, did the kit J contents received agree with the contents listed in the bulletin?
Comments:
• Aircraft hands-on work was J accomplished in estimated time.
Comments:
• Overall, I was satisfied with this Service Bulletin.
Comments:
PLEASE SUPPLY US WITH THE FOLLOWING DATA AND FAX TO (450) 476-7300:
OPERATOR: NAME (Please print) SERVICE CENTER: TELEPHONE:
AIRCRAFT SERIAL NO.: FACSIMILE:
DATE OF SB
INCORPOARTION
THANK YOU FOR ANSWERING THIS EVALUATION FORM
UPON COMPLETION OF THIS EVALUATION FORM/COMPLIANCE SHEET, FAX TO 450-476-7300
No text on this page: it may be a figure. Open the PDF to see it.