Copy · U.S. DOT/FAA - Service Bulletin 2011-0151 - AOM 236A · 3 pages

© Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2011-0151; AD 2011-17-17 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

TextOCR

This text is OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '1cd341b86b78e0136a068cad01ed74971bc0ee7be645559ecf11f5efbc5b6e04'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Page 1OCROpen in PDF

BOMBARDIER AEROSPACE Bombardier Inc.

123 Garratt Blvd Tow aero Bombarder CoS TEL: +1-416-375-4000 Bombardier Q400 All Operator Message No. 236A ATTN: Director/Manager of: Maintenance Engineering Quality Control Flight Operations Procurement/Spares DATE: 11 September 2007 ATA: 3210 MODEL: Q400 SUBJECT: Update - In-service Incident - Right Main Landing Gear Collapse After Landing REFERENCE: /A/ AOM 235, In-service Incident - Right Main Landing Gear Collapse After Landing The following message is being sent to all Bombardier Q400 Operators and Bombardier Aerospace Field Service Representatives.

This message contains information requiring attention and/or action. Please ensure timely and appropriate distribution within maintenance and flight operations departments.

DISCUSSION:

This AOM is being re-issued to clarify compliance time and actions requested.

All Operator Message 235 was previously issued to advise Operators of an incident in which the right hand main landing gear collapsed following landing. A Bombardier / Goodrich team has been dispatched to the site to support the ongoing investigation, along with the Transportation Safety Board of Canada.

Although there have been no findings to-date, we have conducted a preliminary engineering review of the limited information available at this time. Based on this review, Operators may wish to consider performing the following interim actions on a one time basis:

Safety Reminder: Insert the MLG Lock Pin and ensure it fits freely (Refer to Ramp Service Manual Chapter 2 page 45) prior to doing any work in the landing gear area including the recommended tasks below.

D-7534-8-400-AOM-236A Page 1 of 3 (BW/ME) TS001 MW2000 2004-002

Page 2OCROpen in PDF

Within the next 100 flight hours it is recommended to complete the following tasks on a one time basis:

• Clean and perform a General Visual Inspection (GVI) of the MLG stabilizer stay hinge points for general condition and security Clean and inspect (GVI) the MLG stabilizer stay - brace for general condition and security At the next 'A'-Check it is recommended to pay special attention to the following task:

• Lubricate all MLG Stabilizer Stay hinge points and ensure joints freely accept grease (Refer to AMM TASK 12-20-01-640-803) as per the 'A' check. Special attention should be directed to the joints marked on the illustration below, on both sides of the stay brace.

Operators will be advised as the investigation progresses and further information becomes available.

Figure 1: Inspection Areas Inspect Indicated Areas D-7534-8-400-AOM-236A Page 2 of 3 (BW/ME) TS001 MW2000 2004-002

Page 3OCROpen in PDF

Figure 2: Inspection Area Pictures Forward Please direct responses and inquiries to the Technical Help Desk in Toronto at telephone

(416) 375-4000 or facsimile (416) 375-4539 or e-mail: thd.qseries@aero.bombardier.com.

Barry Wilkins, Principal Engineer, In-Service Engineering & Technical Support, and Martin Elliott, Director, In-Service Engineering & Technical Support, Bombardier Aerospace.

D-7534-8-400-AOM-236A Page 3 of 3 (BW/ME) TS001 MW2000 2004-002